How To Check The Components; Thermistor Feature Chart; Low Temperature Thermistors; Medium Temperature Thermistor - Mitsubishi Electric PUZ-A18NHA4 Service Manual

Split-type, heat pump air conditioners outdoor unit
Hide thumbs Also See for PUZ-A18NHA4:
Table of Contents

Advertisement

10-7. HOW TO CHECK THE COMPONENTS

<Thermistor feature chart>

Low temperature thermistors

• Thermistor <Outdoor pipe> (TH3)
• Thermistor <Outdoor 2-phase pipe> (TH6)
• Thermistor <Outdoor> (TH7)
Thermistor R0 = 15k" ± 3%
B constant = 3480 ± 2%
=15exp{3480( 273+t – 273 )}
t (:): R
t
=15exp{3480( 273+(T– 32)/1.8 – 273 )}
T (˚F): R
T
0:[32˚F]
15k"
10:[50˚F]
9.6k"
20:[68˚F]
6.3k"
25:[77˚F]
5.2k"

Medium temperature thermistor

• Thermistor <Heatsink> (TH8)
Thermistor R50 = 17k" ± 2%
B constant = 4170 ± 3%
t (:): Rt =17exp{4170( 273+t – 323 )}
=17exp{4170( 273+(T– 32)/1.8 – 323 )}
T (˚F): R
T
0:[32˚F]
180k"
25:[77˚F]
50k"
50:[122˚F]
17k"
70:[158˚F]
8k"
90:[194˚F]
4k"
High temperature thermistor
• Thermistor <Discharge> (TH4) <for A42>
• Thermistor <Shell> (TH32) <for A12/18/24/30/36>
Thermistor R120 = 7.465k" ± 2%
B constant = 4057 ± 2%
t (:): Rt =7.465exp{4057( 273+t – 393 )}
=7.465exp{4057( 273+(T– 32)/1.8 – 393 )}
T (˚F): R
T
20:[68˚F]
250k"
30:[86˚F]
160k"
40:[104˚F]
104k"
50:[122˚F]
70k"
60:[140˚F]
48k"
1
1
1
1
30:[86˚F]
4.3k"
40:[104˚F]
3.0k"
1
1
1
1
1
1
1
1
70:[158˚F]
34k"
80:[176˚F]
24k"
90:[194˚F]
17.5k"
100:[212˚F]
13.0k"
110:[230˚F]
9.8k"
50
40
30
20
10
0
-20 -10 0 10 20 30 40 50
-4 -14 32 50 68 86 104122 °F
200
150
100
50
0
500
400
300
200
100
0
57
Temperature
25
50
75
100 110 125
77
122
167 212 230 257 °F
Temperature
50
75
100
25
122
167
212
77
Temperature
120
248 °F

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents