Oper ator’s manual K 3000 K 3000 Wet Please r ead the operator’s manual carefully and make sure you understand the instructions before using the machine. E E E E n n n n g g g g l l l l i i i i s s s s h h h h...
KEY T O SYMBOLS Symbols on the mac hine: Symbols in the operator’ s manual: W ARNING! The machine can be a dangerous tool if used incorrectly or Inspection and/or maintenance should carelessly, which can cause serious or be carried out with the motor switched fatal injury to the operator or others.
What is what on the po wer cutter - K 3000? ..4 WHA T IS WHAT? What is what on the po wer cutter - K 3000 Wet? . 5 GENERAL SAFETY PRECA UTIONS Steps bef ore using a new power cutter ....6 Personal protective equipment ......
WHA T IS WHA T? What is what on the po wer cutter - K 3000? Rear handle Type plate Guard for the blade 14” 10 Brush retainer Cutting blade 11 Carbon brushes Locking the axle 12 Guard for the blade 12” (Model version) Front handle 13 Connection for vacuum cleaner Inspection covers...
WHA T IS WHA T? What is what on the po wer cutter - K 3000 Wet? Rear handle 10 Water tap Guard for the blade 11 Water connection with flow limiter Water kit 12 Type plate Cutting blade 13 Brush retainer...
GENERAL SAFETY PRECA UTIONS Mac hine ′ ′ ′ ′ s safety equipment P ower switch lock The po wer switch lock is designed to prevent accidental This section descr ibes the machine ′ s safety equipment, operation of the switch. When the lock (A) is pressed in its purpose, and how checks and maintenance should be the power switch (B) is released.
Page 8
Check that the guard is complete and without any cracks or deformations. Gr ound fault circuit interrupter (K 3000 Wet) Ground fault circuit interrupters are for protection in case an electrical fault should occur. The LED indicates that the ground fault circuit interrupter is on and that the machine can be switched on.
SAFETY INSTRUCTIONS General safety warnings Electrical safety • Power tool plugs must match the outlet. Never modify WARNING! Read all safety warnings and the plug in any way. Do not use any adapter plugs with all instructions. Failure to follow the earthed (grounded) power tools.
SAFETY INSTRUCTIONS Personal safety Power tool use and care • Stay alert, watch what you are doing and use common • Do not force the power tool. Use the correct power tool sense when operaing a power tool. Do not use a for your application.
fitted on the machine. See the instructions under the heading Assembling the cutting blade. Suitable cutting blades Cutting blades K 3000 K 3000 Wet Abrasive blades Yes* Diamond blades Ensure the blade it not cracked or damaged in any other Rescue blade way.
WARNING! Cutting plastics with a cool. diamond blade can cause kickback when the material melts due to the heat Wet cutting with diamond blade (K 3000 Wet) produced when cutting and sticks to the blade. Water cooling, which is used when cutting concrete, cools the blade and increases its service life while also reducing the formation of dust.
SAFETY INSTRUCTIONS General working instructions the material to be cut. This reduces the temperature of the blade and ensures effective cutting. WARNING! This section describes basic • The guard for the cutting equipment should be safety directions for using a power adjusted so that the rear section is flush with the work cutter.
Page 14
SAFETY INSTRUCTIONS How to avoid kickback Pull in Pull in occurs when the disc’s lower section suddenly WARNING! Kickback can happen very stops or when the cut closes. (To avoid, see the heading suddenly and violently; kicking the ”Basic rules” and ”Jamming/rotation”, here below.) power cutter and cutting blade back at Pinching/rotation the user.
Fitting the cutting blade Husqvarna’s blades are approved for hand-held power When the blade is replaced with a new one, check the cutters. Blades are manufactured with three different flange washers and the drive axle. See instructions under diameters of centre holes: 20 mm (0.787"), 22.2 mm (7/...
MAINTENANCE General K 3000 Wet WARNING! Do not use a high pressure washer when rinsing the inside of the machine. The machine can withstand taking in damp air and WARNING! Inspection and/or splashes during the cutting process. Clean water does maintenance should be carried out with not affect the machine’s function.
MAINTENANCE Replacing the carbon brushes Changing the grease The following parts must be dismantled to change the Check the carbon brushes at least once a month. The grease in the gear housing: carbon brushes should be replaced with new brushes if they are worn, cracked or in any other way deformed.
MAINTENANCE Checking water connection with flow limiter Check and clean the filter in the connection regularly and change it when needed. Unscrew the connector. Press out the filter (A) using a screwdriver or the like. Clean or change the filter. When refitting - make sure that the flow limiter (B) is correctly adjusted, with the concave face turned towards the clutch connection.
TECHNICAL DATA Technical data K 3000 K 3000 Wet Motor Protection class Ground fault circuit interrupter Rated voltage, V Europe Great Britain USA / Canada / Japan 100-120 100-120 Australia Rated output, W Europe 2700/12 A 2700/12 A Great Britain...
TECHNICAL DATA Cutting equipment Cutting blade, mm/inches Max. peripheral speed, m/s / ft/s 300/12 350/14 Max. blade speed, rpm 4500 Recommended cable dimensions Cable area 1,5 mm 2,5 mm Input voltage 100-120 V 20 m 40 m Input voltage 220-240 V 30 m 50 m English –...