Air King AKLC70RCB Operating Manual

Exhaust fan with light
Hide thumbs Also See for AKLC70RCB:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

IMPORTANT INSTRUCTIONS -
Models: AKLC70RCB, AKLC70SNS,
AKLC70DRSB
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
A210572216 Rev. A 5-14
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
WARNING:
STALL ENCLOSURE.
WARNING:
USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
CAUTION:
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
WARNING:
g) Read all instructions before installing or using exhaust fan.
www.airkinglimited.com
Exhaust Fan with Light
DO NOT INSTALL OVER A TUB OR MOUNT IN A SHOWER
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO
DO NOT USE IN KITCHENS.
1 of 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AKLC70RCB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Air King AKLC70RCB

  • Page 1: General Safety Information

    IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AKLC70RCB, AKLC70SNS, Exhaust Fan with Light AKLC70DRSB READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Mounting Rails

    INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing the Exhaust Fan Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have: 1 - Grill with Glass Light Lens 1 - Damper Assembly (attached) Figure 3...
  • Page 3 Insert the fan’s plug into the receptacle (Figure 7). Remove light lens from grill as follows: NOTE: If the fan motor plug is AKLC70RCB: Gently twist the light lens counter clockwise to release from the grill. Wire connected to the fan housing AKLC70SLN, AKLC70SLW: Slide the glass light lens out either side of the grill.
  • Page 4 SECTION 7 CAUTION: ALLOW BULBS TO COOL BEFORE REPLACING. Use and Care Changing the Light Bulb: Disconnect power to the unit. Remove light lens from grill by following the instructions in Step 3 of SECTION 6 - Completing the Installation. Replace CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE light bulb(s) with 60 watt maximum, type A19 medium base incandescent bulb(s).
  • Page 5: Limited Warranty

    WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model.
  • Page 6 Mounting Rails 5S1299002 Polarized Receptacle 5S1999001 External Wire Cover 5S2299014 Blower Assembly 5S2234007 Collar/Damper 5S1299111 Light Assembly - AKLC70RCB Gasket - Collar 5S2299015 Light Assembly - AKLC70SNS Interior Wire Cover 5S2234001 Light Assembly - AKLC70DRSB Connector 5S1299008 www.airkinglimited.com A210572216 Rev. A 5-14...
  • Page 7: Instructions Générales De Sécurité

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Modèles: AKLC70RCB, AKLC70SNS, Exhaust Fan with Light AKLC70DRSB LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8: Existing Construction

    INSTRUCTIONS D’INSTALLATION AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION. SECTION 1 Préparation du Ventilateur d’évacuation Sortir le ventilateur de sa boite et confirmer que toutes les pièces sont présentes. En plus du ventilateur d’évacuation vous devriez avoir: 1 - Grille avec les Lentilles de l’éclairage 1 - Ensemble de clapet (attaché) 2 - Vis #8...
  • Page 9 Branchez la prise du ventilateur dans son réceptacle (Figure 7). Figure 7 Remove light lens from grill as follows: AKLC70RCB: Gently twist the light lens counter clockwise to release from the grill. REMARQUE: si le raccord du moteur de Couvercle du ventilateur est raccordé...
  • Page 10: Utilisation Et Entretien

    SECTION 7 AVERTISSEMENT: PERMETTRE À L’AMPOULE DE SE REFROIDIR AVANT DE LA REPLACER. Utilisation et entretien Remplacement de l’ampoule: déconnecter l’alimentation de l’unité. Remove light AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE lens from grill by following the instructions in Step 3 of SECTION 6 - Completing the AU PANNEAU DE SERVICE AVANT DE COMMENCER L’INSTALLATION.
  • Page 11: Guide De Dépannage

    QUE FERA AIR KING : Au cours de la période de garantie, Air King, à son choix, réparera ou remplacera n’importe quelle partie ou pièces qui s’avèrent défectueuses ou remplacera le produit entier par le même modèle ou un modèle comparable.
  • Page 12 Polarized réceptacle 5S1999001 Couvercle de câble externe 5S2299014 Assemblée de la soufflante 5S2234007 Collet / clapet 5S1299111 Assemblée de la lumière - AKLC70RCB 5S5231001 Joint – collet 5S2299015 Assemblée de la lumière - AKLC70SNS 5S5231002 Couvercle de câble Interne 5S2234001 Assemblée de la lumière - AKLC70DRSB...

This manual is also suitable for:

Aklc70snsAklc70drsb

Table of Contents