Air King AKLC70DW Operating Manual

Exhaust fan with light
Table of Contents
  • Français

    • Important Instructions
    • General Safety Information
    • Installation Instructions
    • Figure 10
    • Make Sure Power Is Switched off at
      • Limited Warranty
    • Figure 1

Advertisement

Available languages

Available languages

Quick Links

IMPORTANT INSTRUCTIONS -

: AKLC70DW
Model
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
electric shock and injury to person, including the following:
1. Read all instructions before installing or using exhaust fan.
2. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
3. Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
4. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
and standards, including fire-related construction.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA)
and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and the local code authorities.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO
NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS
AND VAPORS.
210572216 New 7-06
OPERATING MANUAL

GENERAL SAFETY INFORMATION

When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. This unit must be grounded.
9. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off
power unit.
WARNING:
DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL
DEVICE.
WARNING:
A SHOWER STALL ENCLOSURE.
10. NEVER place a switch where it can be reached from a tub or
shower.
WARNING:
www.airkinglimited.com
Exhaust Fan with Light
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
DO NOT INSTALL OVER A TUB OR MOUNT IN
DO NOT USE IN KITCHENS
1 of 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AKLC70DW and is the answer not in the manual?

Questions and answers

Summary of Contents for Air King AKLC70DW

  • Page 1: Important Instructions

    IMPORTANT INSTRUCTIONS - OPERATING MANUAL : AKLC70DW Exhaust Fan with Light Model READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS CAUTION: " MAKE SURE POWER IS SWITCHED OFF AT " SERVICE PANEL BEFORE STARTING INSTALLATION. " SECTION 1 " Preparing the Exhaust Fan 1. Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have: Figure 2 1 - Grill with Glass Light Lens 1 - Damper Assembly (attached)
  • Page 3 SECTION 4 Plug Ducting CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. 1. Connect the ducting to the fan’s duct collar (Figure 5). Secure Screw in place using tape or screw clamp. Always duct the fan to the outside through a wall or roof cap.
  • Page 4: Figure 10

    the wall switch to both the red wire from the fan’s light CAUTION: FAILURE TO SECURE THE GRILL MAY RESULT receptacle and the black wire from the fan’s exhaust IN A RATTLING OR HUMMING NOISE. receptacle. Connect the ground wire from the house to the 5.
  • Page 5: Limited Warranty

    Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you.
  • Page 6: Www.airkinglimited.com

    REPLACEMENT PARTS DIAGRAM Qty. Description Replacement Part # Qty. Description Replacement Part # Fan Housing 5S1234001 Motor 5S2234002 Mounting Rails 5S1299002 Motor Mounting Screw 5S2234003 Collar/Damper 5S1299006 Blower Wheel 5S2234004 External Wire Cover 5S2299014 Cap Screw 5S2234005 Gasket - Collar 5S2299015 Blower Housing 5S2234006...
  • Page 7 INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION Ventilateur combiner, comprend : AKLC70DW Modèle lumière et ventilation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8: Figure 1

    INSTRUCTIONS D’INSTALLATION 2. Installation des Onglets de Montage: à l’aide des guides sur le châssis du ventilateur, aligner le châssis pour qu’il soit à AVERTISSEMENT: VOUS ASSURER QUE L’ALIMENTATION effleurement avec le plafond fini. Positionner le ventilateur EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER pour que les onglets reposent à...
  • Page 9 SECTION 4 Raccord Conduits AVERTISSEMENT: TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX. 1. Raccorder le conduit au collet de conduit du ventilateur (Figure 5). Fixer en place à l’aide de ruban ou de serre-joint. Toujours évacuer le ventilateur vers l’extérieur au travers de chapeau mural ou de toit.
  • Page 10 deux fils Blancs du réceptacle de la lumière et le fil blanc du AVERTISSEMENT: UN MANQUEMENT A BIEN SERRER réceptacle du ventilateur d’évacuation. Raccorder le fil noir LA GRILLE PEUT RESULTER EN UN BRUIT DE CRECELLEMENT provenant du commutateur mural aux deux fils rouge du réceptacle OU DE GRONDEMENT.
  • Page 11 GARANTIE LIMITÉE Tous les produits fabriqués par Air King Limited sont garantis pour un an à partir de la date d’achat contre les défauts de main d’œuvre et/ou de matériel. De plus, tous les ventilateurs / évacuateurs, chaufferettes, combinés ventilateur/ lumière et/ou les chaufferettes et les hottes de cuisine sont garantis pour cinq années à...
  • Page 12 DIAGRAMME DES PIÈCES DE REMPLACEMENT # de pièce # de pièce Qté. Description de remplacement Qté. Description de remplacement Cabinet du ventilateur 5S1234001 Moteur 5S2234002 Traverses de Montage 5S1299002 Vis de Montage de Moteur 5S2234003 Collet / Clapet 5S1299006 Roue de la Soufflante 5S2234004 Couvercle de Câble Externe 5S2299014...

Table of Contents