IMPORTANT INSTRUCTIONS -
Models:
AKF50, AKF80LS, AKF100, AKF80H,
AKF100H, LEDAK50, LEDAK80,
LEDAK100, LEDAK80H, LEDAK100H
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
210572203 Rev. S 2-17
OPERATING MANUAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
injury to person, including the following:
TO REDUCE THE RISK
TO REDUCE THE RISK
SAVE THESE INSTRUCTIONS
CAUTION:
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
a) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.
b) Do not install in a ceiling with thermal insulation value greater
than R40.
WARNING:
WARNING:
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT
ON THE AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE
THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR
BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH
SMALLER DUCTS THAN RECOMMENDED. INSULATION AROUND
THE DUCTS CAN REDUCE ENERGY LOSS AND INHIBIT MOLD
GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT
ACHIEVE THEIR RATED AIRFLOW.
www.airkinglimited.com
Exhaust Fan with Light
FOR GENERAL VENTILATING USE ONLY.
WARNING:
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
DO NOT USE IN KITCHENS.
THE DUCTING FROM THIS FAN TO THE
1 of 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LEDAK80 and is the answer not in the manual?

Questions and answers

Summary of Contents for Air King LEDAK80

  • Page 1 OPERATING MANUAL Models: AKF50, AKF80LS, AKF100, AKF80H, Exhaust Fan with Light AKF100H, LEDAK50, LEDAK80, LEDAK100, LEDAK80H, LEDAK100H READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
  • Page 2: Installation Instructions

    SECTION 4 INSTALLATION INSTRUCTIONS Ducting CAUTION: MAKE SURE POWER IS SWITCHED OFF AT NOTE: 4" OR LARGER RIGID DUCT IS RECOMMENDED FOR BEST PERFORMANCE. SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL SECTION 1 BUILDING CODES.
  • Page 3 terminal of each toggle switch. Connect the Yellow wire from the fan to one of the toggle switches (this is the main light control). Connect the Purple wire from the fan to the other toggle switch (this is the night light control). Use approved methods for all connections. Screw 3c.
  • Page 4 Push the grill up into position (Figure 14). applying outward pressure. Installation is the reverse of removal. Replace with Air King model 26SBL or a compatible GU24 26 watt self ballasted lamp.
  • Page 5: Troubleshooting Guide

    WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model.
  • Page 6: Replacement Parts Diagram

    Mounting Channel 5S1202122 Collar Assembly 5S1299111 Wire Cover Assembly - AKF50, LEDAK50 5S1202621 Wire Cover Assembly - AKF80LS, LEDAK80 5S1202625 Wire Cover Assembly - AKF100, LEDAK100 5S1202622 Wire Cover Assembly - AKF80H, LEDAK80H 5S1202623 Wire Cover Assembly - AKF100H, LEDAK100H...
  • Page 7: Instructions Générales De Sécurité

    INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION Modèles: AKF50, AKF80LS, AKF100, AKF80H, Ventilateur combiner, comprend AKF100H, LEDAK50, LEDAK80, lumière et ventilation LEDAK100, LEDAK80H, LEDAK100H LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ.
  • Page 8 SECTION 4 INSTRUCTIONS D’INSTALLATION Conduits ATTENTION : VOUS ASSURER QUE L’ALIMENTATION REMARQUE : UN CONDUIT PLUS RIGIDE DE 4 PO OU PLUS EST RECOMMANDE POUR UNE EST COUPÉE AU PANNEAU DE SERVICE AVANT DE COMMENCER MEILLEURE PERFORMANCE. L’INSTALLATION. ATTENTION : SECTION 1 TOUS LES CONDUITS DOIVENT ÊTRE CONFORMES AUX CODES DU BÂTIMENT LOCAUX ET NATIONAUX.
  • Page 9 1a. Compartiment de Câblage Extérieur : enlever la vis du couvercle du compartiment à chaque boîte pour effectuer les connexions. Dans la boîte de commutation, connectez câblage et mettre ce couvercle dans un endroit fiable (Figure 6). le fil noir de la maison à la borne commune du commutateur. Connectez le fil noir du ventilateur à...
  • Page 10 L’installation est l’inverse du démontage. Remplacez par une lampe à lumière mixte de 26 watts du modèle Air King 26SBL ou d’un modèle compatible GU24 26 watts. Ampoule LED : Enlevez la lampe en tournant doucement la base de lampe dans le sens contraire des aiguilles d’une montre tout en appliquant une pression extérieure.
  • Page 11: Guide De Dépannage

    QUE FERA AIR KING : Au cours de la période de garantie, Air King, à son choix, réparera ou remplacera n’importe quelle partie ou pièces qui s’avèrent défectueuses ou remplacera le produit entier par le même modèle ou un modèle comparable.
  • Page 12 5S1202122 Assemblée de collier 5S1299111 Assemblée du compartiment du fil - AKF50, LEDAK50 5S1202621 Assemblée du compartiment du fil - AKF80LS, LEDAK80 5S1202625 Assemblée du compartiment du fil - AKF100, LEDAK100 5S1202622 Assemblée du compartiment du fil - AKF80H, LEDAK80H 5S1202623 Assemblée du compartiment du fil - AKF100H.

Table of Contents