10-3. Indoor Unit

10-3-1. Installation Place

• A place which provides the spaces around the indoor unit as shown in the
diagram.
• A place where there are no obstacles near the air inlet and outlet.
• A place which allows easy installation of the piping to the outdoor unit.
• A place which allows the front panel to be opened.
CAUTION
CAUTION
• Direct sunlight to the indoor unit's wireless receiver should be avoided.
• The microprocessor in the indoor unit should not be too close to RF
noise sources.
(For details, see the owner's manual)
Remote control
• A place where there are no obstacles such as a curtain that may block the
signal from the remote control.
• Do not install the remote control in a place exposed to direct sunlight or
close to a heating source such as a stove.
• Keep the remote control at least 1 m apart from the nearest TV set or
stereo equipment (This is necessary to prevent image disturbances or
noise interference).
• The location of the remote control should be determined as shown below.
(Side view)
7 m
Reception range
* : Axial distance
10-3-2. Cutting a Hole and Mounting
Installation Plate
Cutting a hole
(Rear piping)
100
60
(Bottom piping)
100
70
1. After determining the pipe hole position, drill the pipe hole (∅65 mm) at a
slight downward slant to the outdoor side.
NOTE
• When drilling a wall that contains a metal lath, wire lath or metal plate, be
sure to use a pipe hole brim ring sold separately.
(Top view)
Remote
control
Remote control
(Side piping)
45
: Pipe hole (ˇ 65 mm)
Mounting the installation plate and screw position
When the installation plate is directly mounted
on the wall
1. Securely fil t the installation plate onto the wall by screwing it in the upper
and lower parts to hook up the indoor unit.
2. To mount the installation plate on a concrete wall with anchor bolts, use
the anchor bolt holes as illustrated in the below figure.
3. Install the installation plate horizontally in the wall.
Installation plate
(Keep horizontal direction)
ˇ 5 mm hole
Clip anchor
(local parts)
Failure to firmly install the unit may result in personal injury and property
damage if the unit falls.
• In case of block, brick, concrete or similar type walls, make ∅5 mm holes
in the wall.
• Insert clip anchors for appropriate mounting screws 6 .
– 69 –
Floor
Anchor bolt
Projection
15 mm or less
6
Mounting screw
∅4 mm x 25 l
CAUTION
(Unit : mm)
Wall