Toshiba RAS-B10UFV-E Service Manual page 35

Air conditioner split type
Hide thumbs Also See for RAS-B10UFV-E:
Table of Contents

Advertisement

Item
[In starting and in stability]
• Until 12 minutes passed after operation start
FAN AUTO
• When 12 to 25 minutes passed after operation
start and room temp. is 3°C or lower than set temp.
FAN Manual
• Room temp. < Set temp. –4°C
(Table 2) Indoor fan air flow rate <Heating>
Fan speed
RAS-B10UFV-E
level
HEAT
Fan speed
(rpm)
WF
UH
560
WE
H
540
WD
M+
500
WC
440
WB
M
380
WA
380
W9
L+
380
W8
L
300
W7
L-
260
W6
260
W5
UL
260
W4
260
W3
260
W2
SUL
240
W1
240
Operation flow and applicable data, etc.
In starting
RAS-B13UFV-E
Air flow rate
Fan speed
(m3/h)
(rpm)
528
600
510
580
468
520
408
480
342
390
342
390
342
390
258
350
216
340
216
270
216
270
216
270
216
270
198
250
198
240
• When 12 to 25 minutes passed after operation start
and room temp. is higher than (set temp. –3°C)
• When 25 minutes or more passed after operation start
• Room temp. = Set temp. –3.5°C
RAS-B18UFV-E
Air flow rate
Fan speed
Air flow rate
(m3/h)
(rpm)
(m3/h)
570
690
552
670
486
600
444
570
354
520
354
460
354
460
312
400
300
360
228
340
228
340
228
340
228
340
210
320
198
240
– 35 –
Description
In stability
666
642
570
540
486
426
426
366
324
300
300
300
300
282
198

Hide quick links: