Technical Specifications - Bosch ARD-AYK12 Installation Manual

Rfid proximity card reader
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 5
8
en | Installation Manual

TECHNICAL SPECIFICATIONS

Electrical Characteristics
Power Supply Type
Operating Voltage Range 5 - 16 VDC
Maximum Input Current
Tamper Output
Max Cable Distance to
Controller
Output modulation
Card read distance*
RF Modulation
Regulatory Approvals
Environmental Characteristics
Operating Temp. Range
Operating Humidity
Dimensions
Height x Widht X Depth
* Measured using Bosch Proximity Card (P/N ACD-ATR11ISO) or
equivalent. Range also depends on electrical environment and/
or proximity to metal.
Suitable for Outdoor Use
| V 1.2 | 2009.09
Linear type recommended
Standby: 35 mA
Read: 50 mA
Open collector, active low, max
sink current 16 mA
500 ft. (150 meters)
26-bit Wiegand
3.15 inch (8 cm)
ASK
USA: UL 294 & FCC Part 15B
Europe: CE Listed
-25°F to 145°F (-31°C to 63°C )
0 to 95% (non condensing)
3.15 x 1.57 x 0.50 inch
(79.91 x 39.91 x 12.8 mm)
Bosch Sicherheitssyteme GmbH
ARD-AYK12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents