dash brackets and door sheet metal are not acceptable ground points. It is recom-
mended that all security components be grounded at the same location.
h1/2 and h1/11 brown speaker outputs
Connect the BROWN output wires to the BROWN wires of the 518C.
h1/3 gray (-) hood input zone 6
Connect this wire to the hood pin. If the hood is open when the alarm is armed, this
wire will trigger the siren.
h1/4 violet/black tach input
This wire monitors engine speed for BlackJax and door locks. Connect it to the nega-
tive side of the coil or to the uncommon color of any fuel injector. If installing with
Intellistart, only connect the Intellistart wire; DO NOT use this wire.
h1/5 green/white (-) normally closed zone 6
This wire will trigger the alarm if it looses its normally closed ground. Remove this wire
from the ground wire and attach it to a normally grounded item you wish to protect
such as the back of your stereo.