INSTALLING THE PDI-P10LCD TO THE PDI-508C-7 SUSPENSION ARM
1. Remove and save the ¾" Socket Head Cap Screw from the plastic "H" clip.
Remove the plastic "H" clip and discard.
2. Remove the two nose cover retainer bolts. Raise the metal nose cover and
slide the television completely
into the arm's clevis (slot). The
swivel retainer plate should rest
inside the nose of the arm and
the plastic swivel cap beneath
(see picture on previous page).
3. Align the retainer plate's
mounting hole over the arm
mounting hole. Thread the ¾"
Socket Head Cap Screw through
the retainer plate and into the
arm's nose. Tighten.
4. The coax cable in the nose of the arm should be joined with the coax cable
from the television. Wrench tighten the connection and cover by sliding the
plastic boot sections into mating position.
IMPORTANT: Finger only tightening of this cable connection will result in
reliability problems weeks or months later. Because the TV draws its power
current through this connection, eventually the finger-tightened connection will
loosen, develop resistance and prompt a service call. Wrench tighten all "F"
fitting connections!
5. Remove the safety brake pin from the parking brake hole, reattach the acorn
nut to the pin, and store the assembly inside the nose of the arm by attaching it
to the coax cable using the attached plastic clip.
6. Close the metal nose cover onto the nose. Reinstall the two nose cover
retainer bolts.
7. Attach three sets of plastic arm covers (start with long "nose cover" section):
a. Assemble supplied spring pins into
one of the arm cover halves. Pins
should be installed into one cover
side only.
b. Position the Arm Cover halves
around the arm's nose section. Align
exposed pins with the open holes in
the second cover half.
c. Squeeze the two halves together.
When the halves are properly
installed there should only be a thin
seam visible where the halves meet.
d. Repeat steps a, b, c for the elbow
covers and base covers.
8. Connect the coax cable at the base of the arm to the wall bracket "F" fitting.
Wrench tighten. Cycle the arm once or twice to check for free movement.
PDI Communication Systems, Inc.
Phone 937-743-6010
Brake Pin
Nose Cover
Spring
Pin
40 Greenwood Lane
Fax 937-743-5664
PDI-P10LCD USER MANUAL
Document Number PD196-058R3
Nose Cover
Retainer Bolts
Springboro, Ohio 45066
email: pdi@pdiarm.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Persona10 p10lcd

Table of Contents