Timeout detected during self-test of XSB#XX-X.
[Explanation] Because the hardware diagnosis in DR did not complete, a timeout
occurred. There is a possibility that a hardware error occurred.
[Remedy] Find out the cause of the DR failure referring to the monitoring message
and error log. Replace the failed component.
XSB#XX-X will be assigned to DomainID X. Continue? [y|n]:
[Explanation] Confirming whether DR operation is going to be executed or not.
Input "y" to execute it and "n" to stop it.
XSB#XX-X will be configured into DomainID X. Continue? [y|n]:
[Explanation] Confirming whether DR operation is going to be executed or not.
Input "y" to execute it and "n" to stop it.
XSB#XX-X could not be configured into DomainID X due to
operating system error.
[Explanation] An error occurred in DR library of domain OS at configuration
process. The error occurred at configuration management of domain OS.
[Remedy] Find out the cause of the DR failure referring monitoring message and
console message. Try again after resolving cause.
A.2.4

setdcl

XSB is already assigned to an LSB in a running Domain (DomainID
X).
[Explanation] The system board of the specified LSB has already been registered in
DCL.
[Remedy] Power off the domain, or move XSB to the system board pool. Try again.
LSB#00 is already registered in DCL.
[Explanation] The system board of the specified LSB has already been registered in
DCL.
[Remedy] Confirm the domain, LSB and XSB. Setup data correctly.
LSB#00 has not been registered in DCL yet.
[Explanation] The domain and LSB weren't set up, when the DCL of no-mem, no-
io and floating-board was changed.
[Remedy] Set up the domain and LSB. Try again.