Solution hose fitting
hard to connect
Carpet not getting
clean
Carpet too wet
Carpet browning
Solution not flowing
properly
Auto-fill does not
control water level
Pump-out system has
no flow
Pump-out system has
low flow
Corrosion on fittings.
Severe soil conditions
Over saturation
Leaving carpet too wet
Too much chemical
Solution hose connection
Faulty pump
Faulty floor tool valve / Nozzle
Faulty pump switch
Faulty Auto-fill float
Faulty Pump-out switch
Faulty Pump-out pump
Blown fuse
Clogged primary strainer
Clogged secondary strainer

86327530 NINJA WARRIOR 1200 PSI

Clean with steel wool. Soak in acetic acid (white
vinegar). Lubricate lightly with silicone base
lubricant.
Make several passes at right angles to each
other. Use a pre-spray.
Adjust solution pressure to lower settings. Make
several passes without spray
Check for loss of vac pressure
Check label for correct solution concentration
Check for positive connection
Repair or replace
Repair or replace
Repair
Replace float
Replace Pump-out switch
Replace Pump-out pump
Replace fuse
Clean primary strainer
Clean secondary strainer
Maintenance