Connections
Connection in Extraction Mode
When installing in extraction mode, con-
nect the hood to the chimney using ei-
ther a flexible or rigid pipe ø 150 or 125
mm, the choice of which is left to the
installer.
• To install a ø 125 mm air exhaust con-
nection, insert the reducer flange G
on the hood body air outlet and the
adapting ring ø120-125 F on the re-
ducer flange.
• Fix the pipe in position using sufficient
pipe clamps (not supplied).
• Remove any activated charcoal fil-
ters.
Connection in Recirculation Mode
• When the hood is fitted in the recircu-
lation mode the Air Outlet Connection
H should be fitted as illustrated .
• Fit the (optional) charcoal filters by
repeating the following operation on
each side of the motor housing. Place
the two key hole slots in the filter and
turn the filter clockwise to lock the
filter in position.
WARNING: It is a possible fire hazard if
the metal grease filters are not cleaned
and the charcoal filters replaced regu-
larly.
IMPORTANT:
When installing this product in recircula-
tion mode over a gas hob or Gas coo-
ker and between adjacent wall mounted
cupboards. The installer must ensure
that there is no gap between the edge
of the canopy and wall cup-boards.
Installation
����
����
�
�
�
H
��
electrolux 7
����
B
A