8-7. Wiring Diagram
(1) For China
Armature
Choke coil
(2) For other countries
Armature
8-8. Remaining Reassembly
Remaining reassembly can be accomplished by following the disassembly procedures in reverse.
8-9. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance and conduct the dielectric strength
test.
Insulation resistance:
Dielectric strength:
8-10. No-Load Current Value
After no-load operation for 30 minutes, the no-load current value should be as follows:
Stator
Stator
7 M
or more with DC 500 V Megohm Tester.
AC 4000 V/1 minute, with no abnormalities
Voltage (V)
Current (A) (max.)
Switch
Noise
suppressor
Fig. 6
Switch
Fig. 7
• • • • • • • • • • • • • •
220
230
1.3
1.2
--- 9 ---
Cord
Cord
220 V -- - 230 V