Download Print this page

Insulation Test; No-Load Current Value; Wiring Diagram - Hitachi G 10SS2(S) Service Manual

Advertisement

On completion of disassembly and repair, measure the insulation resistance and dielectric strength.
Insulation resistance: 7 MΩ or more with a 500 VDC megohm tester
Dielectric strength test: 4,000 VAC/minute, with no abnormalities ---------- 230 V
After no-load operation for 30 minutes, the no-load current values should be as follows.
Voltage
Current max.
Fig. 5
Stator [9]<9>
Black
Black
Stator [9]<9>

Insulation test

2,500 VAC/minute, with no abnormalities ---------- 110 V

No-load current value

110 V
2.8 A

Wiring diagram

Pushing Button Switch [32]<31>
Black
2
C2
Gray
C1
1
Black
230 V
1.1 A
Controller
-4-
Red
Varistor (A) Ass'y
[43]<42>
Brown
Blue
White

Advertisement