11.21 CONTINUITY DIAGRAM
Model
915055, 057, 059, 065, 067, 501, 502
The diagrams below show the various states of connection for electrical components.
The solid lines on switches show continuity.
NOTE: All switches are viewed from the rear.
Key Switch
Off
PTO Switch
3
4
1
Disengaged
(down position)
Seat Switch
1
2
Operator
Off Seat
Solenoid
Not Energized
5 for Serial Numbers Below
Run / Light
9
3
9
7
4
1
7
Disengaged
(down position)
1
2
Operator
On Seat
Energized
Run
Relay
87
86
85
87A
30
Not Energized
Parking Brake Switch
Button Out
Neutral Switch
Button Out
11 - 54
Start
87
86
85
87A
30
Energized
Button In
Button In
PE0770