10.12 CONTINUITY DIAGRAM
The diagrams below show the various states of connection for electrical components.
The solid lines on switches show continuity.
NOTE: All switches are viewed from the rear.
Key Switch
B
PTO Switch
3
4
1
DISENGAGED
(down position)
Seat Switch
1
2
OPERATOR
OFF SEAT
Solenoid
NOT ENERGIZED
M
L
B
L
S
Y
S
G
A
A
OFF
RUN / LIGHT
9
3
7
4
1
ENGAGED
(up position)
1
2
OPERATOR
ON SEAT
ENERGIZED
M
B
M
L
Y
S
Y
G
A
RUN
Relay
9
86
7
NOT ENERGIZED
Brake Switch
BUTTON UP
Neutral Switch
3
1
BUTTON OUT
10 - 40
M
B
L
S
Y
G
G
A
START
87
87A
85
86
30
ENERGIZED
1
2
BUTTON DOWN
4
3
2
1
BUTTON IN
87
87A
85
30
1
2
PE0520
4
2