Download Print this page

Delta SIG80L Installation And Operating Instructions

Ventilation fan / light / night light

Advertisement

Quick Links

INSTALLATION AND OPERATING INSTRUCTIONS
VENTILATION FAN / LIGHT / NIGHT LIGHT
READ AND SAVE THESE INSTRUCTIONS

GENERAL SAFETY INFORMATION

1.
Make sure that the electric service supply voltage is AC
120V, 60Hz.
2.
Follow all local electrical and safety codes, as well as the
National Electrical Code (NEC) and the Occupational
Safety and Health Act (OSHA).
3.
Always disconnect the power source before working on
or near the ventilating fan, motor or junction box.
4.
Protect the power cord from sharp edges, oil, grease, hot
surfaces, chemicals or other objects.
5.
Do not kink the power cord.
6.
Do not install the unit where ducts are con gured as
shown in Fig. A.
7.
Provide suction parts with proper ventilation.
8.
This unit is UL listed for use over a bathtub or shower
when installed in a GFCI protected branch circuit.
9.
These ventilating fans are intended for residential usage
only.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.
Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
2.
Before servicing or cleaning the unit, switch the power
o on the service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3.
Installation work and electrical wiring must be done by
quali ed person(s) in accordance with all applicable
codes and standards, including re-rated construction.
4.
Su cient air is needed for proper combustion and
exhausting of gases through the ue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE) and local code authorities.
5.
When cutting or drilling into the wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6.
Ducted fans must always be vented to the outdoors.
MODELS SIG80L / SIG110L / SIG110HL / SIG110DL
7.
If this unit will be installed over a tub or shower, it must
be marked as appropriate for the application and be
connected to a GFCI (Ground Fault Circuit Interrupter) –
protected branch circuit.
8.
Do not use this unit with any other solid-state control
devices. Solid-state control devices may cause harmonic
distortion, which can cause a motor humming noise.
9.
NEVER place a switch where it can be reached from a tub
or shower.
10. (Required for installation in Canada only). Do not install
in a ceiling thermally insulated to a value greater than
R40.
Turning angle too large
T
o
o
m
a
n
y
e
b l
o
w
s
CAUTION
1.
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2.
Not for use in cooking areas. (Fig. B)
3.
This product must properly connect to the grounding
conductor of the supply circuit.
4.
To reduce the risk of injury to persons, install the fan at
least 7 feet (2.1m) above the oor.
Do not install above or
Page 1.
Duct shrink
E
b l
o
w
n
e
r a
h t
e
b
o
d
Body
Fig. A
Cooking area
inside this area
Cooking
floor
Equipment
Fig. B
y

Advertisement

loading

Summary of Contents for Delta SIG80L

  • Page 1: General Safety Information

    MODELS SIG80L / SIG110L / SIG110HL / SIG110DL Page 1. INSTALLATION AND OPERATING INSTRUCTIONS VENTILATION FAN / LIGHT / NIGHT LIGHT READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION If this unit will be installed over a tub or shower, it must...
  • Page 2: Supplied Accessories

    MODELS SIG80L / SIG110L / SIG110HL / SIG110DL Page 2. SUPPLIED ACCESSORIES Note: Remove the tape from the damper and adaptor before installation. Part name Appearance Quantity 1. Using suspension brackets Grille 1-1. Sliding suspension brackets are available to allow the...
  • Page 3: Duct Connection

    MODELS SIG80L / SIG110L / SIG110HL / SIG110DL Page 3. 2. Duct connection Humidity Models: SIG110HL Dual Speed Models: SIG110DL Inside Outside JUNCTION BOX SWITCH BOX Tape WHITE LIGHT SWITCH Duct Body YELLOW WHITE NIGHT LIGHT SWITCH Gradient Ceiling BLACK 1°~2°...
  • Page 4: Operation

    MODELS SIG80L / SIG110L / SIG110HL / SIG110DL Page 4. 4-2-1. Lock the grille screw (M4×30) into the grille bracket. 4-2-5. Install the light bulb and close the lens cover to lock into place. GU24 Lamp (26W Max.) 4-2-2. Insert the grille bracket module into the main body, and E12 Lamp (4W Max.)
  • Page 5: Maintenance Warning

    5. The warranty does not cover if user does not comply with manufacturer’s installation manual. 6. To qualify for warranty service, you must notify Delta Electronics at the address or telephone number below. 7. Delta Electronics shall have no liability to the original owner-user with...

This manual is also suitable for:

Sig110lSig110hlSig110dl