Download Print this page

Operation - Delta SIG80L Installation And Operating Instructions

Ventilation fan / light / night light

Advertisement

4-2-1. Lock the grille screw (M4×30) into the grille bracket.
4-2-2. Insert the grille bracket module into the main body, and
use grille bracket screw (M4×6) to a x the main body.
Insert area
4-2-3. Mount the grille onto the main body by using the
location screw.
4-2-4. Attach the grille onto the main body by using the grille
screw and nut, respectively.
Grille bracket
Grille bracket
screw (M4x6)
Main body
Grille module
Nut
Grille screw
(M4x30)
MODELS SIG80L / SIG110L / SIG110HL / SIG110DL
4-2-5. Install the light bulb and close the lens cover to lock
into place.
GU24 Lamp (26W Max.)
E12 Lamp (4W Max.)
Lock lens cover

5. Operation

Delay timer control
(SIG110DL)
or Humidity preset control
(SIG110HL)
TIME(min)
TIME(min)
CFM
CFM
Low speed air volume preset control
(SIG110DL, SIG110HL)
SIG110DL
SIG110HL
control options
control options
TIME(min)
CFM
%RH
CFM
Single Models: SIG80L, SIG110L
5-1. Single speed control mode: Turn the POWER switch on to
operate at single speed mode - the LED indicator will be
green.
Humidity Models: SIG110HL
5-2. Humidity control mode: Turn the POWER switch on to
operate at humidity control mode - the LED indicator will
be blue. When the ambient humidity is higher than the
user-adjustable set-point, the fan will run at full speed.
When the ambient humidity is lower than the set-point,
the fan will continue to run at full speed until a 10- minute
time delay has elapsed, and then will automatically
change to the user-adjustable low speed air ow.
5-3. Full speed mode: Turn the MODE switch on to operate at
full speed mode - the LED indicator will be amber.
5-4. Humidity tolerance is about ±10%. As the fan is used
throughout the years, dust will accumulate periodically.
This will in uence the precision of the humidity detector.
Readjusting the humidity switch will address this issue.
Factory setting: low speed air ow 40CFM, humidity 60%RH.