Laser Preferred Timeout (DS9808-LR/LL Only)
Parameter # F1h 7Dh
If Multifunction Mode Triggering is set to Laser Preferred Decoding, use this parameter to set the time period that
the laser remains on before using the imager if a decode does not occur.
To set the timeout, scan the bar code below, followed by two bar codes from
correspond to the desired time in the range of 0.1 to 9.9 seconds. To correct an error or change the selection, scan
Cancel on
page
D-2. The default is 1.5 seconds.
Laser Preferred Timeout
Dual Trigger Debounce Timeout (DS9808-LR/LL Only)
Parameter # F1h 7Ah
Set a time period in which both triggers must be pulled in order for the digital scanner to recognize this as a dual
trigger pull. In other words, if you pull Trigger A, then Trigger B after this timeout expires, the digital scanner
behaves as if you pulled Trigger A only.
To set the timeout, scan the bar code below, followed by two bar codes from
correspond to the desired time in the range of 0.00 to 0.99 seconds. Enter a trailing zero for single digit numbers.
For example, to set a Debounce Timeout of 0.50 seconds, scan the bar code below, then scan the 5 and 0 bar
codes. To correct an error or change the selection, scan Cancel on
The default is 0.05 seconds.
User Preferences & Miscellaneous Digital Scanner Options 4 - 25
page
Dual Trigger Debounce Timeout
Appendix D, Numeric Bar Codes
Appendix D, Numeric Bar Codes
D-2.