3-2 Outdoor Unit
• SH12ZSGX
UQ12SGGE
No
Parts
1
Common
Work
2
Fan and
Motor
3-4
Procedure
1) Loosen 2 fixing screws and separate the
cover valve.
2) Separate the connection wire from the
terminal block.
3) Loosen 4 fixing srews and separate the cabi
front.
4) Loosen 2 fixing screws and separate the cabi
side LF.
5) Loosen 2 fixing screws of the cabi side RH.
1) Do "1", above.
2) Separate the connection wire of the motor
fan.