GETTING TO KNOW YOUR VACUUM

1) Cover/motor assembly
2) Cover latch (2)
3) Waterproof switch
4) Top carry handle
5) On-board accessory storage
6) Threaded inlet
7) Threaded blower outlet
8) Tank
9) Cord wrap posts
10) Tank drain cap
11)Foam filter
12) Re-usable filter
13) Cartridge filter
14) 30L Dust bag
15) 2pc. Extension wands
16) Thread-on hose
17) 10" floor sweep
18) Crevice tool
ELECTRICAL INFO &
SPECIFICATIONS
POWER SUPPLY- WARNING: YOUR VACUUM MUST BE
CONNECTED TO A 110V, MINIMUM 15-AMP. BRANCH CIRCUIT.
FAILURE TO CONNECT IN THIS WAY CAN RESULT IN INJURY
FROM SHOCK OR FIRE.
GROUNDING- Your vacuum must be properly grounded. Not all outlets
are properly grounded. If you are not sure if your outlet is properly
grounded, have it checked by a qualified electrician. WARNING: IF
NOT PROPERLY GROUNDED, THIS VACUUM CAN CAUSE
ELECTRICAL SHOCK, PARTICULARLY WHEN USED IN DAMP
LOCATIONS. TO AVOID SHOCK OR FIRE, IF THE POWER CORD IS
WORN OR DAMAGED IN ANY WAY, HAVE IT REPLACED
IMMEDIATELY.
If this vacuum should malfunction or breakdown, grounding provides a
path of least resistance for electric current, to reduce the risk of
electric shock. This vacuum is equipped with a cord having an
equipment grounding conductor and grounding plug. The plug must be
plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
110V OPERATION- As received from the factory, your vacuum is ready
to run for 110V operation. This vacuum is intended for use on a circuit
that has an outlet and a plug which looks like the one illustrated in Fig.1.
EXTENSION CORDS- The use of any extension cord will cause some
loss of power. Use the table in Fig.2 to determine the minimum wire size
(A.W.G-American Wire Gauge) extension cord. Use only 3-wire
extension cords which have 3-prong grounding type plugs and 3-hole
receptacles which accept the tool's plug. For circuits that are further
away from the electrical circuit box, the wire size must be increased
proportionately in order to deliver ample voltage to the motor. Refer to
Fig.2 for wire length and size.
GETTING TO KNOW YOUR VACUUM,
ELECTRICAL INFO & SPECIFICATIONS
SPECIFICATIONS
Model..............................................................................8530LP
Voltage................................................................................110V
Horsepower ............................................................5 HP (peak)
Amperage ............................................................................10A
Phase ........................................................................................1
Hertz ..................................................................................60Hz
Tank size ................................................8 Gallon (US)/30 liters
Air flow ........................................................................145 CFM
Vacuum pressure (inches of water) ................................68.4"
PROPERLY GROUNDED OUTLET
CURRENT CARRYING
PRONGS
GROUNDING
PRONG
FIGURE 1
LENGTH OF
CONDUCTOR
0-25 FEET
26-50 FEET
51-100 FEET
FIGURE 2
WIRE SIZES REQUIRED
(AMERICAN WIRE GAUGE)
110V LINES
NO.16
NO.16
NO.14