Voltage Selector Switch
The power available to each receptacle depends on the position of the
voltage selector switch.
Switch Position
120 V ONLY
120 V/240 V
120V ONLY Position
When the voltage selector switch is in the 120V ONLY position, you do
not need to spread the load over the receptacles. You must, however,
make sure the load on any receptacle does not exceed its available
power shown in the preceding table and the total load does not
exceed 45.8 amps.
120V/240V Position
When the voltage selector switch is in the 120V/240V position, you
must balance the load. Divide the load between the two sets of
receptacles shown below. Balancing is necessary because each set of
receptacles is powered by only one power producing circuit that can
produce a maximum of 22.9 amps.
Set of
Receptacles
1
3
4B
2
4A
Receptacle
1
2
3
4A
4B
1
2
3
4A-4B
Total Current
Available
22.9 A
22.9 A
OPERATION
Available Power
30 A at 120 V
20 A at 120 V
20 A at 120 V
30 A at 120 V
None
22.9 A at 120 V
20 A at 120 V
20 A at 120 V
22.9 A at 240 V
Power Producing
Circuit