Bryant 574D----A Product Data

Bryant 574D----A Product Data

Legacy 13 seer single-packaged air conditioner and gas furnace system with puronr (r-410a) refrigerant single and three phase 2 to 5 nominal tons (sizes 24-60)

Advertisement

574D- - - - A
LEGACYt 13 SEER
SINGLE- - PACKAGED AIR CONDITIONER AND GAS FURNACE SYSTEM
WITH PURONR (R- - 410A) REFRIGERANT SINGLE AND THREE PHASE
2 TO 5 NOMINAL TONS (SIZES 24- - 60)
Fig. 1 - - Unit 574D- -- -A
Single- -Packaged Products with Energy- -Saving Features and
PuronR refrigerant.
S Up to 13.5 SEER
S Up to 80.4% AFUE
S Factory- -Installed TXV
S ECM Motor- -Standard
S Direct Spark Ignition
S Low Sound Levels
S Dehumidification Feature

FEATURES/BENEFITS

One- -piece heating and cooling units with low sound levels, easy
installation, low maintenance, and dependable performance.
Puron Environmentally Sound Refrigerant is Bryant's unique
refrigerant designed to help protect the environment. Puron is an
HFC refrigerant which does not contain chlorine that can harm the
ozone layer. Puron refrigerant is in service in millions of systems,
proving highly reliable, environmentally sound performance.
Easy Installation
Factory- -assembled package is a compact, fully self- -contained,
combination gas heating/electric cooling unit that is prewired,
pre- -piped, and pre- -charged for minimum installation expense.
These units are available in a variety of standard and optional
heating/ cooling size combinations with voltage options to meet
residential and light commercial requirements. Units are
lightweight and install easily on a rooftop or at ground level. The
high tech composite base eliminates rust problems associated with
ground level applications.

Product Data

Innovative Unit Base Design
On the inside a high- -tech composite material will not rust and
incorporates a sloped drain pan which improves drainage and helps
inhibit mold, algae and bacterial growth. On the outside metal base
rails provide added stability as well as easier handling and rigging.
Convertible duct configuration
Unit is designed for use in either downflow or horizontal
applications. Each unit can be converted from horizontal to
downflow and includes horizontal duct covers. Downflow
operation is provided in the field to allow vertical ductwork
connections. The basepan seals on the bottom openings to ensure a
positive seal in the vertical airflow mode.
Efficient operation High- -efficiency design
(Seasonal Energy Efficiency Ratios) of up to 13.5 and AFUE
(Annual Fuel Utilization Efficiency) ratings as high as 80.4%.
Energy- -saving, direct spark ignition saves gas by operating only
when the room thermostat calls for heating. Standard units are
furnished with natural gas controls. A low- -cost field installed kit
for propane conversion is available for all units.
Low NOx units are designed for California installations. These
A09034
models meet the California maximum oxides of nitrogen (NOx)
emissions requirement of 40 nanograms/joule or less as shipped
from the factory and MUST be installed in California Air Quality
Management Districts and wherever a Low NOx rule exists.
Durable, dependable components Compressors are designed
for high efficiency. Each compressor is hermetically sealed against
contamination to help promote longer life and dependable
operation. Each compressor also has vibration isolation to provide
quieter operation. All compressors have internal high pressure and
overcurrent protection.
Monoport inshot burners produce precise air- -to- -gas mixture,
which provides for clean and efficient combustion. The large
monoport on the inshot (or injection type) burners seldom, if ever,
requires cleaning. All gas furnace components are accessible in one
compartment.
Turbo- -tubulart heat exchangers are constructed of aluminized
steel for corrosion resistance and optimum heat transfer for
improved efficiency. The tubular design permits hot gases to make
multiple passes across the path of the supply air.
In addition, dimples located on the heat exchanger walls force the
hot gases to stay in close contact with the walls, improving heat
transfer.
ECM Motor is standard on all 574D- -- -A models.
Direct- -drive PSC (Permanent Split Capacitor) condenser- -fan
motors are designed to help reduce energy consumption and
provide for cooing operation down to 40_F (4.4_C) outdoor
temperature. Motormasterr II low ambient kit is available as a
field- -installed accessory.
Thermostatic Expansion Valve - - A hard shutoff, balance port
TXV maintains a constant superheat at the evaporator exit (cooling
cycle) resulting in higher overall system efficiency.
Refrigerant system is designed to provide dependability. Liquid
filter driers are used to promote clean, unrestricted operation. Each
unit leaves the factory with a full refrigerant charge. Refrigerant
service connections make checking operating pressures easier.
1
offers SEER

Advertisement

Table of Contents
loading

Summary of Contents for Bryant 574D----A

  • Page 1: Product Data

    Turbo- -tubulart heat exchangers are constructed of aluminized steel for corrosion resistance and optimum heat transfer for Puron Environmentally Sound Refrigerant is Bryant’s unique improved efficiency. The tubular design permits hot gases to make refrigerant designed to help protect the environment. Puron is an multiple passes across the path of the supply air.
  • Page 2: Table Of Contents

    High and Low Pressure Switches provide added reliability for the Horizontal metal duct covers are standard with insulation come compressor. with the unit and cover the horizontal duct openings. These can be left in place if the units are converted to downflow. Indoor and Outdoor coils are computer- -designed for optimum heat transfer and efficiency.
  • Page 3: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE 574D --- --- Variations Type of Unit FE --- Economizer (3 Phase Only) 574D --- Single Packaged GP--- Tin plated indoor coil hairpins and Stainless Steel Gas Heating/Electric HX (Single Phase Only) Cooling Unit GS --- Stainless Steel HX SE --- Economizer and Stainless Steel HX (3 Phase Electrical Supply Only)
  • Page 4 AHRI* CAPACITIES Cooling Capacities and Efficiencies NET COOLING UNIT 574D- - - - A NOMINAL TONS STANDARD CFM EER** SEER† CAPACITIES (Btuh) 23,000 11.0 13.2 2- -1/2 1000 28,400 11.2 13.5 1200 34,400 11.0 13.0 3- -1/2 1400 40,500 11.2 13.2 1600 46,500...
  • Page 5: Physical Data 5

    PHYSICAL DATA UNIT SIZE 24040 24060 30040 30060 36060 36090 42060 42090 NOMINAL COOLING CAPACITY (ton) 2 ---1/2 2 ---1/2 3 ---1/2 3 ---1/2 NOMINAL HEATING INPUT (Btu/hr) 40,000 60,000 40,000 60,000 60,000 90,000 60,000 90,000 SHIPPING WEIGHT** lb. SHIPPING WEIGHT** (kg) Scroll COMPRESSORS Quantity...
  • Page 6 PHYSICAL DATA (CONT) UNIT SIZE 48090 48115 48130 60090 60115 60130 NOMINAL CAPACITY (ton) NOMINAL HEATING INPUT (Btu/hr) 90,000 115,000 130,000 90,000 115,000 130,000 SHIPPING WEIGHT** lb SHIPPING WEIGHT** kg Scroll COMPRESSORS Quantity REFRIGERANT (R --- 410A) Quantity lb 10.0 10.0 10.0 Quantity (kg.)
  • Page 7: Options And Accessories

    OPTIONS AND ACCESSORIES FACTORY FIELD ITEM DESCRIPTION INSTALLED INSTALLED OPTION ACCESSORY Coil Options Base unit with tin plated indoor coil hairpins Compressor Start Kit assists compressor start--- up by providing additional starting torque on sing phase units Compressor Start Kit only.
  • Page 8: Vertical Economizer

    ECONOMIZER COIL FILTER ECONOMIZER CAULK BOTTOM CORNER OF ECONOMIZER SIDE VIEW ON EACH SIDE FI LTER Vertical Economizer COIL ECONOMIZER BASE FLANGE ON BASE DETAIL FILTER RACK BEND FLANGE AT 90 ° -SCREW TO DIVIDER WITH 1-IN. (25 mm) SCREW Horizontal Economizer TOP FILTER RACK EV APORATOR...
  • Page 9 UNIT DIMENSIONS - - 574D- - - - A24- - 36 A09469...
  • Page 10 UNIT DIMENSIONS - - 574D- - - - A42- - 60 A09470...
  • Page 11: Accessory Dimensions

    ACCESSORY DIMENSIONS Dashed lines show cross support location for large basepan units. HVAC unit HVAC unit basepan base rails Sealing Gasket Roofcurb Anchor screw Wood nailer* Flashing field supplied Roofcurb* Insulation (field supplied) Roofing material field supplied Cant strip field supplied SMALL/COMMON CURB A09413 *Provided with roofcurb...
  • Page 12: Selection Procedure

    SELECTION PROCEDURE (WITH EXAMPLE) 1. Determine cooling and heating requirements at 4. Determine fan speed and power requirements at design conditions: design conditions. Given: Before entering the air delivery tables, calculate the total static pressure required. From the given example, the Wet Coil Pressure Required Cooling Capacity (TC) .
  • Page 44: Typical Piping And Wiring

    TYPICAL PIPING AND WIRING ROOF-MOUNTING CURB ROOF RETURN-AIR FLEXIBLE DUCT SUPPLY-AIR FLEXIBLE DUCT CEILING CONCENTRIC DIFFUSER BOX (FIELD-SUPPLIED) A09230 INDOOR THERMOSTAT RETURN FROM TOP COVER POWER SOURCE DISCONNECT PER NEC* FROM GAS LINE *NEC - NATIONAL ELECTRICAL CODE A09231...
  • Page 45: Application Data

    APPLICATION DATA Maximum cooling airflow — To minimize the possibility of Condensate trap — A 2- -in. (51 mm) condensate trap must be condensate blow- -off from the evaporator, airflow through the units field supplied. should not exceed 450 cfm per ton. Ductwork —...
  • Page 46: Electrical Data

    ELECTRICAL DATA NOMINAL VOLTAGE RANGE COMPRESSOR POWER SUPPLY UNIT V- -PH- -HZ MOCP** 574D----A24040 12.8 58.3 21.3 574D----A24060 12.8 58.3 21.3 574D----A30040 12.8 64.0 21.3 574D----A30060 12.8 64.0 21.3 574D----A36060 16.7 79.0 28.0 574D----A36090 16.7 79.0 28.0 574D----A42060 17.9 112.0 29.6 208/230--1--60 574D----A42090...
  • Page 47 CONNECTION TYPICAL WIRING SCHEMATIC 208/230- -1- - 60 A09282C...
  • Page 48 LADDER TYPICAL WIRING SCHEMATIC 208/230- - 1- - 60 A09282L...
  • Page 49 CONNECTION TYPICAL WIRING SCHEMATIC 208/230- -3- - 60 A09264C...
  • Page 50 LADDER TYPICAL WIRING SCHEMATIC 208/230- - 3- - 60 A09264L...
  • Page 51: Controls

    CONNECTION TYPICAL WIRING SCHEMATIC 460- - 3- - 60 CONNECTION WIRING DIAGRAM DANGER: ELECTRICAL SHOCK HAZARD DISCONNECT POWER BEFORE SERVICING NOTES: SCHEMATIC IF USED 1. IF ANY OF THE ORIGINAL WIRES FURNISHED ARE REPLACED, THEY MUST BE REPLACED WITH TYPE 460-3-60 90 DEG.
  • Page 52 LADDER TYPICAL WIRING SCHEMATIC 460- - 3- - 60 LADDER WIRING DIAGRAM DANGER: ELECTRICAL SHOCK HAZARD DISCONNECT POWER BEFORE SERVICING UNIT COMPONENT ARRANGEMENT USE COPPER CONDUCTORS ONLY OUTDOOR FAN SECTION FIELD SUPPLY 460 VAC, 60 HZ, 3PH COMPRESSOR INDOOR FAN CONTROL BOX AREA SECTION SECTION...
  • Page 53 CONTROLS On the loss of the thermostat call for cooling, 24 V is removed Operating sequence from both the “Y1/Y” and “G” terminals (provided the fan switch Heating - - On a call for heating, terminal “W” of the thermostat is is in the “AUTO”...
  • Page 54: Guide Specifications

    GUIDE SPECIFICATIONS Packaged Gas Heating/Electric Cooling Units 3. Condenser fan shall be direct drive propeller type with alu- minum blades riveted to corrosion resistant steel spiders, be Constant Volume Application dynamically balanced, and discharge air vertically. HVAC Guide Specifications D. Compressor: Size Range: 2 to 5 Tons, Nominal Cooling 1.
  • Page 55 GUIDE SPECIFICATIONS (CONT) N. Special Features Available: 10. High Altitude Propane Conversion Kit: Shall consist of all required hardware to convert to propane 1. Coil Options gas heat operation at 2001 to 6000 ft (611 to 1829 m) above Base unit with tin plated indoor coil hairpins available as a sea level.
  • Page 56 Catalog No. PDS574D---05 E2011 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 08/11 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Table of Contents