Service Function Explanation - Toyotomi TA3-A80GWI Service Manual

Room air conditioner
Table of Contents

Advertisement

EMERGENCY AND TEST OPERATION
Emergency Operation
• Use this operation only when the remote controller is out of order or lost.
• When the emergency operation switch is pressed, beep starts once, which
means the start of this operation.
• In this operation, the system automatically selects the operation modes, cooling
(or heating when available) according to the room temperature, as follows.
Operation
Temperature
mode
ABOVE 23°C
COOLING
BELOW 23°C
HEATING
• It is not possible to operate in dry mode.
Test Operation
Test operation switch is same as emergency one.
• Use this operation only for testing the performance of the machine in the condition
where the room temperature is less than 16°C.
• Continue to press the test operation switch for more than 5 seconds.
After you hear twice beep, release your finger from the switch: the cooling
operation starts with the air flow speed "HI."
• If the test operation switch is pressed more than 10 seconds, it doesn't work.
• After 30 minutes, test operation ends automatically.
HOW TO RELEASE EMERGENCY AND TEST OPERATION
• In case of releasing during those operations, you can either push emergency operation switch once more or
apply operation using remote control.
You will hear a beep sound and emergency/ test operation is released.
• If you release the operation by remote control, operation will continue as setting of the remote control
automatically.
INTERFERENCE PREVENTION OF SIGNALS FROM THE REMOTE CONTROLLERS
When two indoor units used in the same room, interference of the signals may happen. To avoid this, alternative
signal model B can be selected by the following. (Ex-factory setting is mode A)
• Remote controller side
• Indoor unit side
(Each Operations Details)
<Remote control unit>
Ex-factory setting (Mode A)
Have "J1"on the PC
board short-circuited
by soldering (Mode B)

SERVICE FUNCTION EXPLANATION

Designated
Timer mode
temperature
26°C
CONTINUOUS
23°C
CONTINUOUS
: Have "J1" on the PC board short-circuited by soldering.
: Cut "R13" on the PC board.
Receive
Not receive
Not receive
Receive
Air flow
AUTOMATIC
AUTOMATIC
Ex-factory setting (Mode A)
Cut R13 on the PC board (Mode B)
– 7 –
Beep
Twice beep
J1
J1
Soldering
<Indoor unit>