1.
POWER SUPPLY DURING REPAIRS
In this unit, about 10 seconds after power is supplied (8.4V) to the
battery terminal using the service power cord (J-6082-223-A), the
power is shut off so that the unit cannot operate.
This following two methods are available to prevent this. Take note
of which to use during repairs.
Method 1.
Connect the servicing remote commander RM-95 (J-6082-053-B)
to the LANC jack, and set the remote commander switch to the
"ADJ" side.
Method 2.
Use the DC IN terminal. (Use the AC power adaptor.)
2.
TO TAKE OUT A CASSETTE WHEN NOT EJECT (FORCE EJECT)
1 Refer to 2-2. to remove the front panel block assembly.
2 Refer to 2-3. to remove the cabinet (R) block assembly.
3 Refer to 2-4. to remove the cassette lid assembly.
4 Refer to 2-4. to remove the battery panel block assembly.
5 Refer to 2-4. to remove the cabinet (L) assembly.
6 Disconnect CN974 of VC-234 board.
7 Add +5V from the DC POWER SUPPLY and unload with a
pressing the cassette compartment.
9 Let go your hold the cassette
compartment and rise the cassette
compartment to take out a cassette.
SERVICE NOTE
Battery terminal 3
8 Pull the timing belt in the direction of
arrow A with a pincette while pressing
the cassette compartment (take care
not to damage) to adjust the bending
of a tape.
Pincette
Timing belt
Timing belt
— 7 —
Battery terminal #
DC IN terminal
Battery SIG terminal
Press the cassette compartment not to
rise the cassette compartment
[DC power supply]
Disconnect CN974
of VC-234 board.
Adjust the bending of a tape
(+5V)
Loading motor