Checking System Power Module Using Tester - Hitachi RAS-50FH5 Service Manual

Hide thumbs Also See for RAS-50FH5:
Table of Contents

Advertisement

HOW TO CHECK SYSTEM POWER MODULE

Checking system power module using tester

Set tester to resistance range (X 100)
If indicator does not swing in the following conductivity check, the system power module is normal.
(In case of digital tester, since built-in battery is set in reverse direction, + and – terminals are reversed.)
CAUTION
If inner circuit of system power module is disconnected (open), the indicator of tester will not swing and this may
assumed as normal. In this case, if indicator swings when
+ and – terminals are connected in reverse of diagram
below, it is normal. Furthermore, compare how indicator swings at U, V and W phases. If indicator swings the same way
at each point, it is normal.
+
+
+
+
P1
N1
P2
U
P1
N1
P2
U
+
+
L2
L1
L2 L1
+
+
W
V
W
V
– 116 –

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rac-50yh5Ras-50yh5

Table of Contents