Auto Operation; Infrared Remote Control - Hitachi RAS-50FH5 Service Manual

Hide thumbs Also See for RAS-50FH5:
Table of Contents

Advertisement

AUTO FRESH DEFROSTING
Q7
After the ON/OFF button is pressed
to stop heating, the outdoor unit is
still working with the OPERATION
lamp lighting.

AUTO OPERATION

Q8
Fan speed does not change when
fan speed selector is changed
during auto operation.
NICE TEMPERATURE RESERVATION
Q9
When on-timer has been
programmed, operation starts before
the preset time has been reached.
Q10
Does ÒNice temperature reservationÓ
function operate during dehumidifying?
Q11
Even if the same time is preset,
the operation start time varies.

INFRARED REMOTE CONTROL

Q12
Timer cannot be set.
Q13
The current time display
disappears soon.
Q14
The timer has been programmed,
but the preset time disappears.
A7
Auto Fresh Defrosting is carried out : the
system checks the outdoor heat exchanger
and defrosts it as necessary before stopping
operation.
A8
At this point fan speed is automatic.
A9
This is because ÒNice temperature reservationÓ
function is operating. This function starts
operation earlier so the preset temperature is
reached at the preset time. Operation may start
maximum 60 minutes before the preset time.
A10
It does not work. It works only during cooling
and heating.
A11
This is because ÒNice temperature reservationÓ
function is operating. The start time varies
according to the load of room. Since load varies
greatly during heating, the operation start time is
corrected, so it will vary each day.
A12
Has the clock been set? Timer cannot be set
unless the clock has been set.
A13
The current time disappears
in approx. 10 seconds. The
time set display has priority.
A14
Is the current time past the preset time?
When the preset time reaches the current
time, it disappears.
– 97 –
When the current time is
set the display flashes for
approx 3 minutes.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rac-50yh5Ras-50yh5

Table of Contents