Ras-24Gkp-Es2 / Ras-24Ga-Es2 - Toshiba RAS-24GKHP-ES2 Service Manual

Split wall type
Table of Contents

Advertisement

5-3. RAS-24GKP-ES2 / RAS-24GA-ES2

Cooling
0.39m
(Connecting pipe)
∅12.7
O.D.:12.7mm
P
Packed valve
(∅12.7)
Gas container connection (Reinstall etc.)
Cooling
Accumulator
Compressor
PA290X3CS-4MU1
Cooling
50Hz
Standard
Cooling
Overload
Low temperature
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Indoor unit
Heat exchanger
Cross flow fan
Condenser
Propeller fan
Outdoor unit
Standard
Surface temp. of heat
pressure P
exchanger interchanging
(MPaG)
pipe T1 (° C)
3.183
4.040
1.651
- 17 -
FILE NO. SVM-06020
T1
Packed valve
(∅6.35)
Capillary tube
∅2.0x900s
Refrigerant
R410A 1.70kg
Mark(
)means check points of Gas Leak.
Fan speed
(indoor)
7.0
High
11.7
High
-0.4
Low
0.49m
(Connecting pipe)
∅6.35
O.D.:6.35mm
Ambient temp.
conditions DB/WB
(° C)
Indoor
Outdoor
27/19
35/24
32/23
43/26
21/15
21/15

Hide quick links: