10-1. Indoor Unit

No.
Part name
1
Front panel
2
Electrical part
assembly

10. PART REPLACEMENT

Procedures
How to remove the front panel
1) Stop the operation of the air conditioner and turn off
its main power supply.
2) Pull the inlet grille toward you to open it and remove
4 screws fixing the front panel.
3) Remove upper 3 hooks of the front panel from the
back body.
4) Open the horizontal grille right below by hand.
5) Pull the lower side of the front panel toward you
until it touches the horizontal grille to remove it.
How to mount the front panel
1) Mount the front panel with the inverse procedure of
"How to remove the front panel".
2) Push 3 places (right, left and center) of the air
outlet.
3) Check the gap between the front panel and the
back body.
If you operate the air conditioner in cooling or dry
operation without pushing the 3 places, the surface
of the front panel may be covered with frost and
have dewdrops.
1) Remove the front panel with the procedure 1.
2) Remove the screw fixing the electrical part box.
3) Remove the drain guide.
4) Remove the connector (3P x 2) for the fan motor
and the connector (6P) for the louver motor from
the microcomputer assembly.
5) Remove the screw for the earth, and pull the
electrical part base toward you to remove it from the
main unit.
6) Pull out the TC sensor from the sensor holder.
(2)
(3) Drain guide
When assembling the electrical parts
assembly, make the connecting cable
U-shaped and put it in the drain pan.
- 65 -
FILE NO. SVM-06020
Remarks
(2)
4-screws
(3)
(4)
(5) screws
(3P X 2)
6P
(2) screws
(6) TC sensor
(2)