1

Listing and Code Approvals

A. Appliance Certifi cation
Model
Mt. Vernon Pellet Stove
Laboratory
OMNI Test Laboratories, Inc.
Report No.
061-S-68-6
Type
Solid Fuel Room Heater/Pellet Fuel
Burning Type
Standard
ASTM E1509-04, ULC S627-00 and
ULC/ORD-C1482-M1990 Room Heater
Pellet Fuel Burning type and (UM)
84-HUD, Mobile Home Approved.
FCC
Complies with Part 15 of FCC Rules.
Operation is subject to the following
two conditions: (1) this device may not
cause harmful interference, and (2) this
device must accept any interference
received, including interference that may
cause undesired operation.
NOTICE: This installation must conform with local codes. In
the absence of local codes you must comply with the ASTM
E1509-04, ULC S627-00, (UM) 84-HUD and ULC/ORD-
C-1482.
B. BTU & Effi ciency Specifi cations
EPA Certifi ed:
Effi ciency:
BTU Input:
Heating Capacity:
Vent Size:
Fuels:
Shipping Weight:
*BTU will vary, depending on the type of fuel you use in your
appliance. Consult your Quadra-Fire dealer for best results.
C. Glass Specifi cations
This stove is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
D. Electrical Rating
115 VAC, 60 Hz, Start 5 Amps, Run 1.25 Amps
6
4.16 grams per hour
Up to 86.5%
14,600 - 52,500 / hr
Up to 3,000 square feet depend-
ing on climate zone
3" or 4" Type "L" or "PL"
Pellets, Shelled Field Corn,
Wheat and Black Sunfl ower
Seeds
449 lbs
E. Mobile Home Approved
• This appliance is approved for mobile home installa-
tions when not installed in a sleeping room and when
an outside combustion air inlet is provided.
• The structural integrity of the mobile home fl oor, ceil-
ing, and walls must be maintained.
• The appliance must be properly grounded to the
frame of the mobile home and use only Listed pellet
vent Class "L" or "PL" connector pipe.
• Outside Air Kit, part OAK-ACC must be installed in a
mobile home installation.
Fire Risk
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided by,
the following actions:
• Installation and use of any damaged appliance.
• Modifi cation of the appliance.
• Installation other than as instructed by Hearth & Home
Technologies.
• Installation and/or use of any component part not approved by
Hearth & Home Technologies.
• Operating appliance without fully assembling all components.
• Operating appliance without legs attached (if supplied with unit).
• Do NOT Overfi re - If appliance or chimney connector glows,
you are overfi ring.
Any such action that may cause a fi re hazard.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualifi ed
installer, service agency or your dealer.
NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products, their
specifi cations and/or price without notice.
Quadra-Fire is a registered trademark of Hearth & Home
Technologies.
7034-276C
WARNING
June 18, 2014