Sensor setup
SENSOR SETUP
SENSOR RECORD TIME
15
ALARM OUT TIME
20
MOTION SENSITIVE SETUP
CHANNEL-1 TYPE:MOTION + N-C
CHANNEL-2 TYPE:MOTION + N-O
CHANNEL-3 TYPE:NORMAL CLOSE
CHANNEL-4 TYPE:NOT INSTALLED
PRESS (#$), THEN (
)
PRESS(! ) TO EXIT
1.Not installed.
2. Normal open.
3. Normal close.
4. Motion +N-C
5. Motion + N-O
In normal close mode, if the cable line connected between the sensor and the
DVR is cut off by an intruder, the unit will start recording.
In normal open mode, the cable line connected between the sensor and the
unit is cut off by an intruder, the unit will not start recording.
:
Sensor setting notes
1. After "sensor/alarm" installation, come back to "RECORD SCHEDULE" to
select "S" (sensor record) as record mode in the specified period of time.
The unit will accordingly start recording upon alarming during the specified
time.
If finished the sensor and alarm hardware setting. Please press "● "button on
the DVR front panel. Then the DVR will enter the record "stand-by" mode.
Each sensor input corresponds to each camera:
Sensor input #1 corresponds to camera #1.
Sensor input #2 corresponds to camera #2.
Sensor input #3 corresponds to camera #3.
Sensor input #4 corresponds to camera #4.
To trigger multiple cameras for alarm recoding simply wiring one sensor to
multiple sensor inputs.
SENSOR RECORD TIME:
Recording duration once sensor being
triggered.
ALARM OUT TIME:
It controls how long ( in second) the
alarm sounds after being triggered.
SENSOR TRIGGER MODES:
The unit provides 5 different modes for
variant uses:
2. SENSOR RECORD TIME:
This function is setting how long recording will be stop after the alarm symptom
disappear. If alarm symptom didn't disappear, recording won't stop.
Is it possible to set one of the following choices: 5s, 10s, 15s, 20s, 25s and 30s
(seconds).
3. ALARM OUT TIME:
This function is setting how long alarm out will be stop after the alarm symptom
disappear. If alarm symptom didn't disappear, alarm out won't stop.
Is it possible to set one of the following choices: 0s, 5s, 10s, 15s, 20s, 25s,
30s and CONT (continues).
4. MOTION SENSITIVE SETUP:
Use this option to adjust the Motion sensitiviy. There are 9 step of sensitivity: 1
more sensitive, 9 less sensitive.
5. There are 5 different mode for sensor setting:
NOT INSTALLED, NORMAL-CLOSE, NORMAL-OPEN, MOTION+NO and
MOTION+NC:
CHANNEL-1
TYPE: NORMAL-CLOSE
CHANNEL-2
TYPE: NORMAL-OPEN
CHANNEL-3
TYPE: MOTION+N-O
CHANNEL-4
TYPE: MOTION+N-C
In NORMAL-COLSE mode, if the cable line connected to the sensor through
DVR is cut off by an intruder, the sensor recording start.
In NORMAL-OPEN mode, if the cable line connected to the sensor through
DVR is short by an intruder, the sensor recording start.
NOTE
1. A switch setting on the back panel may be used to convert the operation
format from NTSC to PAL, or vice versa.
2. RESET(Initialization): to make the board to reset. Press "#". button 5 times
in the normal view mode. Be aware that all the information (including the
password) will be lost. After reset, the password will be set as the default value
(111111)