D. Deodorizing Control
i. Control condition
Control at cooling/dry operation and auto fan speed setting.
No Deodorizing Control is performed during ON timer standby operation and during Anti-freezing control prevention.
ii. Operation
The odor status is arranged as below and it is shifted as follow.
* When COMP is ON
* When COMP is OFF
* Start from 4 if the Thermostat is OFF during the start operation.
8.1.8.

Outdoor Fan Motor Operation

• • • • 6 pole induction, 1 speed 780 rpm (XE9CK), 810 rpm (XE12CK).
• • • • It starts when compressor starts operation and it stops 30 seconds after compressor stops operation.
(Shift to 4 when COMP is OFF)
(Shift to 1 when COMP is ON)
1 → 2 → 3
4 → 5 → 4 ←→ 5
23
CS-XE9CKE CU-XE9CKE / CS-XE12CKE CU-XE12CKE