Values of T1, T2, and T3 depend on remote control setting temperature, as shown in below table. After the adjustment of T1, T2
and T3 values, the operation mode for that particular environment and remote control setting is judged and performed, based on
the above operation mode chart, every 30 minutes.
Remote Control Setting Temperature (°C)
There is a temperature shifting on T1, T2, and T3 if the operation mode judged is changed from Cooling/Soft Dry to Heating or vice
verse.
Operation Mode change from
Cooling/Soft Dry → Heating
Heating → Cooling/Soft Dry
Example of operation mode chart adjustment:
From the above table, if remote control setting temperature = 25,
T1 = 25 + 7 = 32; T2 = 25 + 6 = 31; T3 = 25 - 7 = 18
The operation mode chart for this example is as shown in below figure and the operation mode to be performed will depend on
indoor intake air temperature and outdoor air temperature at the time when the judgment is made.
8.1.7.
Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
• • • • Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)
[Cooling, Dry, Fan]
Remote Control
—
Tab (rpm)
SHI
XE9CK
1250
XE12CK
1340
[Heating]
Remote Control
—
Tab (rpm)
SSHI
XE9CK
1350
XE12CK
1490
16 ~ 18
19 ~ 22
23 ~ 26
27 ~ 30
O
O
Hi
Me+
1200
1100
1310
1200
O
O
SHi
Me+
1270
1160
1410
1330
T1
+10
+8
+7
+6
Temperature shifts (°C)
O
O
O
Me
Me-
Lo
1000
900
800
1090
980
880
O
O
O
Me
Me-
Lo
1050
940
840
1250
1170
1100
19
CS-XE9CKE CU-XE9CKE / CS-XE12CKE CU-XE12CKE
T2
T3
+8
-5
+7
-7
+6
-7
+5
-8
-2
+2
—
—
Lo-
SLo
SSLo
780
730
780
730
—
—
Lo-
SLo
SSLo
790
730
840
730
—
720
720
—
720
720