Mitsubishi Electric City Multi PUMY-P36NHMU Technical & Service Manual page 22

Split-type, heat pump air conditioners
Hide thumbs Also See for City Multi PUMY-P36NHMU:
Table of Contents

Advertisement

PUMY-P36NHMU
SYMBOL
TB1
Terminal Block <Power Supply>
TB3
Terminal Block <Comunication Line>
TB7
Terminal Block <Centralized Control Line>
MC
Motor For Compressor
MF1,MF2
Fan Motor
21S4
Solenoid Valve<Four-Way Valve>
63H
High Pressure Switch
63L
Low Pressure Switch
63HS
High Pressure Sensor
SV1
Solenoid Valve<Bypass valve>
TH3
Thermistor<Outdoor Pipe>
TH4
Thermistor<Discharge>
TH6
Thermistor<Low Pressure Saturated>
TH7
Thermistor<Outdoor>
TH8
Thermistor<Heatsink>
Reactor
DCL
ACTM
Active Filter Module
CE
Main Smoothing Capacitor
Caution for electrical work
Use copper supply wires.
Cautions when Servicing
WARNING: When the main supply is turned off, the voltage [340 V] in the main capacitor will drop to 20 V in approx. 2
!
minutes (input voltage: 240 V). When servicing, make sure that LED1, LED2 on the outdoor circuit board goes out, and then
wait for at least 1 minute.
• Components other than the outdoor board may be faulty: Check and take corrective action, referring to the service manual.
Do not replace the outdoor board without checking.
NOTES:
1.Refer to the wiring diagrams of the indoor units for details on wiring of each indoor unit.
Self-diagnosis function
The indoor and outdoor units can be diagnosed automatically using the self-diagnosis switch
(SW1) and LED1, LED2 (LED indication) found on the multi-controller of the outdoor unit.
LED indication : Set all contacts of SW1 to OFF.
• During normal operation
• The LED indicates the drive state of the controller in the outdoor unit.
Bit
1
Compressor
Indication
52C
operated
• When fault requiring inspection has occurred
The LED alternately indicates the inspection code and the location of the unit in which
the fault has occurred.
PUMY-P36NHMU-BS
NAME
SYMBOL
P.B.
Power Circuit Board
TABU/V/W
Connection Terminal<U/V/W-Phase>
TABS/T
Connection Terminal<L/N-Phase>
TABP1/P2/P
Connection Terminal<DC Voltage>
Connection Terminal<DC Voltage>
TABN1/N2/N
DS2,DS3
Diode Bridge
IPM
Power Module
N.F.
Noise Filter Circuit Board
LI/LO
Connection Terminal<L-Phase>
NI/NO
Connection Terminal<N-Phase>
EI,E2
Connection Terminal<Ground>
52C
52C Relay
C.B.
Controller Circuit Board
SW1
Switch<Display Selection>
SW2
Switch<Function Selection>
SW3
Switch<Test Run>
SW4
Switch<Model Selection>
SW5
Switch<Function Selection>
2
3
4
21S4
SV1
(SV2)
PUMY-P48NHMU
NAME
M-NET P.B.
5
6
7
Always lit
-
-
22
PUMY-P48NHMU
2
SYMBOL
NAME
SW6
Switch<Function Selection>
SW7
Switch<Function Selection>
SW8
Switch<Function Selection>
SWU1
Switch<Unit Address Selection, 1s digit>
SWU2
Switch<Unit Address Selection, 10ths digit>
CNLVB
Connector<To N.F. Board CN52C>
(Symbol of Board is CNLVB)
SS
Connector<Connection For Option>
CN3D
Connector<Connection For Option>
CN3S
Connector<Connection For Option>
CN3N
Connector<Connection For Option>
CN51
Connector<Connection For Option>
LED1,LED2
LED<Operation Inspection Display>
LED3
LED<Power Supply to Main Microcomputer>
F1,F2
Fuse<T6,3AL250V>
X501~505
Relay
M-NET Power Circuit Board
TP1
ConnectionTerminal<Ground>
[Example]
When the compressor and
SV1 are turned during cooling
operation.
8
1 2 3 4 5 6 7 8
-BS
2