Product Specifications; Cs-Xe9Dke Cu-Xe9Dke - Panasonic CS-XE9DKE Service Manual

Table of Contents

Advertisement

CS-XE9DKE CU-XE9DKE / CS-XE12DKE CU-XE12DKE

3 Product Specifications

3.1.

CS-XE9DKE CU-XE9DKE

Cooling Capacity
Heating Capacity
Moisture Removal
Power Source (Phase, Voltage, Cycle)
Airflow Method
Air Volume
Lo
Me
Hi
Noise Level
Electrical Data
Input
Running Current
EER
COP
Starting Current
Piping Connection Port
(Flare piping)
Unit
kW
kcal/h
BTU/h
kW
kcal/h
BTU/h
l/h
Pint/h
ø
V
Hz
OUTLET
INTAKE
3
m
/min (cfm)
3
m
/min (cfm)
3
m
/min (cfm)
Heating; 10.6 (370)
dB (A)
Cooling; High 39, Low 26
Heating; High 40, Low 27
Power level dB
W
A
W/W (kcal/hw), BTU/hw
W/W (kcal/hw), BTU/hw
A
inch
G ; Half Union 3/8"
inch
L ; Half Union 1/4"
6
CS-XE9DKE
2.6 (0.60 - 3.00)
2,240 (520 - 2,580)
8,870 (2,050 - 10,200)
3.6 (0.60 - 5.00)
3,100 (520 - 4,300)
12,300 (2,050 - 17,100)
1.6
(3.4)
Single
230
50
SIDE VIEW
Cooling; 6.5 (231)
Heating; 7.1 (249)
Cooling; 8.1 (286)
Heating; 8.8 (312)
Cooling; 9.9 (350)
Cooling; 30.0 (1,060)
Cooling; High 50
Heating; High 51
Cooling; 700 (115 - 880)
Heating; 900 (110 - 1,400)
Cooling; 3.3
Heating; 4.0
Cooling; 3.71(3.20), 12.7
Heating; 4.00 (3.44), 13.7
4.00
G ; 3-way valve 3/8"
L ; 2-way valve 1/4"
CU-XE9DKE
TOP VIEW
Cooling; 46
Heating; 47
Cooling; High 59
Heating; High 60