3.0 AdjusTmenT
3.1
FlAme chArAcTerIsTIcs
It's important to periodically perform a visual check of the pilot and burner flames.
compare them to the illustrations provided.
FIGURE 3.1.1
3.2
venTurI AdjusTmenT
Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will
cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow
immediately; allow 15 to 30 minutes for the final flame color to be established.
FIGURE 3.2a
PILOT
BURNER
ELECTRODE
FLAME
SENSOR
FLAME MUST ENVELOP
UPPER 3/8" TO 1/2" OF
FIGURE 3.1.2
3/8" - 1/2"
Air shutter Openings both Burners
lp
ng
7/16"
3/16"
AIR
SHUTTER
OPENING
FIGURE 3.2b
W415-0713 / 11.25.08