Adjustment; Flame Characteristics; Venturi Adjustment; Replacements - Napoleon B81NS-1 Installation And Operation Manual

High definition 81 see thru mineral rock burner assembly
Hide thumbs Also See for B81NS-1:
Table of Contents

Advertisement

Available languages

Available languages

installation

3.0 adjustment

EN
3.1

flame characteristics

It's important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
illustration provided. If any flames appear abnormal,
call a service person.
3.2

venturi adjustment

This appliance has an air shutter that has been factory set open according to
the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carbonization. Opening the air shutter will cause
a more blue flame, but can cause flame lifting from the burner ports. The flame
may not appear yellow immediately; allow 15 to 30 minutes for the final flame
colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!
note:
It is important that the orifice is securely inserted into the venturi.

4.0 replacements

WARNING
!
Failure to position the parts in accordance with this manual or failure to use only parts specifi cally approved
with this appliance may result in property damage or personal injury.
Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts can
be ordered through your Authorized dealer / distributor.
For warranty replacement parts, a photocopy of the original invoice will be required to honour the
claim.
When ordering replacement parts always give the following information:
Model & Serial Number of appliance
Installation date of appliance
Part number
Description of part
Finish
Parts, part numbers, and availability are subject to change without notice.
Parts identifi ed as stocked will be delivered within 2 to 5 business days for most delivery
destinations.
Parts not identifi ed as stocked will be delivered within a 2 to 4 week period, for most cases.
Parts identifi ed as 'SO' are special order and can take up to 90 days for delivery.
6
W415-0808 / E / 05.11.18
VENTURI ADJUSTMENT CHART
NG
3/16" (4.8mm)
P
7/16" (11mm)
ADD IMAGE
HERE
36.1
VENTURI
BURNER
AIR
SHUTTER
OPENING
ORIFICE
33.1
26.1