Bank Programming Screen Description - E.F. Johnson LTR-Net 7243 Service Manual

7.5vdc 1 and 4 watts part no. 242-7243-xxx
Table of Contents

Advertisement

This screen is used to create a new bank or edit a current bank. It is displayed by selecting the Edit > Banks menu (see
Section 3.6.11) or clicking one of the
added or edited in the System Display No. drop-down list and then select the desired parameters. Then make the changes by
clicking the Change button (this is an Add button if adding a system). To delete a system from the bank, select it from the
drop-down list or in the list at the bottom of the screen and then click the Delete button. When finished programming the
bank, click the Done button or click Cancel to exit without saving any changes. At least one bank must be programmed even
if bank select is not used.
Parameter
Bank Name This is an eight-character name given to the bank. It is displayed when banks are selected (Section 2.4.1).
Otherwise, it is used only to identify it during programming.
Emergency
The emergency switch is not available with this transceiver.
System/Grp
Home
Selects the home system/group selected by the Home select function on the bank (Section 2.4.6).
System/Grp
Bank Scan
Programs the default scan status (on or off) when the bank is selected (Section 2.4.1).
Enable
System
Systems can be assigned unique display numbers in each bank. This drop-down list selects the number that is
Display No.
displayed when the system is selected in the bank.
System
This is a drop-down list of all currently programmed systems that selects the system being added to the bank or
edited. Systems can also be selected by clicking them in the list at the bottom of the screen.
Add To Scan
Selects the default scan list status of the selected system in the bank. This status is valid only until the first time
List
it is changed by the FCN S.A/D switch. Cycling power does not reselect the default status (Section 2.6.7).
Change/Add
This is a Change button when editing a system and an Add button when adding a system. It is clicked to make
Button
the changes to the selected system.
Delete
Deletes the currently selected system from the bank.
Button
Table 3-5 Bank Programming Screen Description
buttons in the toolbar. In the above screen, select the number of the system to be
Description
3-19
PROGRAMMING
November 2001
Part No. 001-7240-001

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ltr-net 7200 series

Table of Contents