Refrigeration Cycle Diagram; Ras-13Ukp-Es / Ras-13Ua-Es - Toshiba RAS-13UKP-ES Service Manual

Air-conditioner split wall type
Hide thumbs Also See for RAS-13UKP-ES:
Table of Contents

Advertisement

5-1. RAS-13UKP-ES / RAS-13UA-ES

Cooling
0.39m
(Connecting pipe)
∅9.52
O.D.:9.52mm
P
Packed valve
(∅9.52)
Cooling
Cooling Compressor
Cooling
50Hz
Standard
Cooling
Overload
Low temperature
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)

5. REFRIGERATION CYCLE DIAGRAM

Indoor unit
Heat exchanger
Cross flow fan
PA150X2T-4FM
Condenser
Propeller fan
Outdoor unit
Standard
pressure P
(MPaG)
0.95
1.15
0.65
T1
Refrigerant
R-22 : 0.86 kg.
Mark(
)means check points of Gas Leak.
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
10.0
13.0
2.0
– 12 –
FILE NO. SVM-02005(1)
0.49m
(Connecting pipe)
∅6.35
O.D.:6.35mm
Packed valve
(∅6.35)
Capillary tube
∅1.5x900S
Ambient temp.
conditions DB/WB
Fan speed
(°C)
(indoor)
Indoor
High
27/19
High
32/23
Low
21/15
Outdoor
35/24
43/26
21/15