4. SPECIFICATION OF ELECTRICAL PARTS

4-1. Indoor Unit

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Switching transformer (T01)
4
Microcontroller unit (IC30)
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Bridge rectifier (DB01)
8
Capacitor (C02)
9
Fuse (F01)
10
Varistor (R21, R22)
11
Resistor (R01)
12
Louver motor
13
Relay (Comp., RY01)

4-2. Outdoor Unit (RAS-13UA-ES)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Type
MMF-240-20-4A-1
———
SWT-47
TMP87CM40AN-2C67
———
LC*SS11V-06270
D3SBA60
KMH400VSSN47M22S
TSCR6.3A
15G561K
RF-2TK5R6
MP24GA
DI12D1
Type
Output (Rated) 1100W, 2poles, 1 phase, 220 – 240V, 50Hz
PA150X2T-4FM
Winding resistance (Ω)
(at 20°C)
Output (Rated) 30W, 6poles, 1 phase, 220 – 240V, 50Hz
HF-240-30B
Winding resistance (Ω)
(at 20°C)
SK-50FMP1.5U2 AC 500V, 1.5µF
DS371356CPNB
AC 370V, 35µF
– 10 –
FILE NO. SVM-02005(1)
Specifications
AC Motor with 135°C thermo fuse
10kΩ at 25°C
10kΩ at 25°C
27mH, 600mA
4A, 600V
47µF, 400V
T6.3A, 250VAC
560V
5.6Ω, 2W
12VDC
Rating 20A/AC250V, 12VDC
Specifications
C-R
2.49
Red-Black
245
C-S
3.95
White-Black
388