Refrigeration Cycle Diagram; Ras-13Ukpx-T2 / Ras-13Uax-T2 - Toshiba RAS-13UKPX-T2 Service Manual

Split wall type
Table of Contents

Advertisement

5-1. RAS-13UKPX-T2 / RAS-13UAX-T2

Cooling
0.39m
(Connecting pipe)
∅12.7
O.D.:12.7mm
P
Packed valve
(∅12.7)
Cooling
Cooling Compressor
Cooling
50Hz
Standard
Cooling
Overload
Low temperature
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)

5. REFRIGERATION CYCLE DIAGRAM

Indoor unit
Heat exchanger
Cross flow fan
RM5515FNE96
Condenser
Propeller fan
Outdoor unit
Standard
pressure P
(MPaG)
0.48
0.60
0.42
T1
Refrigerant
R-22 : 0.80 kg.
Mark(
)means check points of Gas Leak.
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
13.0
18.0
2.0
– 14 –
FILE NO. SVM-02003
0.49m
(Connecting pipe)
∅6.35
O.D.:6.35mm
Packed valve
(∅6.35)
Capillary tube
∅1.7x500S
Ambient temp.
conditions DB/WB
Fan speed
(°C)
(indoor)
Indoor
High
27/19
High
32/23
Low
21/15
Outdoor
35/24
43/26
21/15

Hide quick links: