Pressure Sensor - GE Profile PTWN8055MMS Technical Service Manual

4.5 doe cu. ft. stainless steel capacity washer
Hide thumbs Also See for Profile PTWN8055MMS:
Table of Contents

Advertisement

4. Lift the dispenser from the component tray.
5. Remove the 2 Phillips-head screws that attach
the dispenser inlet to the dispenser.
6. Lift the dispenser inlet out of the dispenser.
Note: Pink plastic pressure fi ttings are used on
the dispenser inlet for a tight fi t and to reduce the
possibility of leaks.

Pressure Sensor

The pressure sensor is connected by a clear
pressure hose to an air reservoir near the bottom
of the outer tub and operates by a frequency (kHz)
signal to the power board.
When the water level rises in the washer tub,
air is trapped in the reservoir. As the water level
rises, the air pressure in the reservoir increases.
The pressure is translated into an electrical
signal (frequency) by the pressure sensor.
The frequency will vary from approximately 27
kHz (empty tub) to 21 kHz (full tub).
This frequency can be measured at the pressure
sensor between the purple and orange wires.
To remove the pressure sensor:
1. Place the control panel in the service position.
(See
Control Panel
2. Disconnect the wire harness.
3. Push outward on the 3 fl exible plastic tabs,
and then lift the pressure sensor from the
component tray.
Disconnect
4. Squeeze and slide down the hose clamp.
5. Remove the pressure hose from the pressure
sensor.
Hose Clamp
Pressure Hose
– 20 –
.)