Noise Filter

The noise fi lter helps to block out line noise that
could adversely affect the washer control system.
To remove the fi lter:
1. Place the control panel in the service position.
(See
.)
Control Panel
2. Remove the 2 Phillips-head screws that attach
the fi lter to the component tray.
3. Lift, and then turn fi lter over.
4. Disconnect the wire harness.
Note: 15-amp line fuse is not replaceable. Noise
fi lter is replaced as an assembly.
L1 and Neutral
Input Harness
Line Fuse
L1 and Neutral Output Harness

RF Choke

The RF choke consists of a donut shaped ferrite
core that helps to prevent electrical interference to
nearby electronic devices.
L1 and neutral input wires, and the ground wire are
wrapped around and through the ferrite core.
To access the choke, it is necessary to place the
control panel in the service position. (See
.)
Panel
Choke
Ground Wire
– 21 –