Parts
Thermal cut-out (OVEN)
Oven lamp
High voltage capacitor
Magnetron
Power transformer
Fuse
thermal cut-out(Magnetron)
WARNING: WIRING / RE-WIRING.
Before carrying out any work; carry out 3D
checks.
1. Disconnect the supply
2. Door opened and wedge open.
3. Discharge the high voltage capacitor.
RE-WIRING.
Ensure the following:
1. Wires must not touch:
a) High voltage parts.
(Magnetron, high voltage transformer, high
voltage capacitor and high voltage rectifier).
b) Parts that become hot.
(Heating elements, oven lamp, oven cavity
magnetron and high voltage transformer).
SOI 01.05 FV
TEST DATA AT A GLANCE
Symbol
TC01
OL
C
MG
T
F1
TC02
WIRING/RE-WIRING
2. Positive lock connectors are fitted correctly.
3. Wires are connected correctly as per pictorial
4. No wire leads are trapped by the outer wrap.
31/33
Value / Data
125°C
240-250V 25W
0.91µF AC 2100V(EU)
0.88µF AC 2100V(UK)
Filament < 1
Ω
∞
Filament – chassis
ohm.
Ω
Filament winding < 1
Secondary winding Approx. 160
Primary winding Approx. 2
F8A 250V
125°C
c) Sharp edges.
(Bottom plates, oven cavity, waveguide
flange, chassis support and other metallic
parts).
d) Movable parts.
( Fan blade, any motor, switch).
Ensure the locking pin is located correctly.
diagram.
.
Ω
.
Ω
599 36 78-06