FUSE
NIOSE FILTER
Figure 0-1 Oven Schematic-OFF Condition, Door Closed.
FUSE
NIOSE FILTER
Figure 0-2 Oven Schematic-ON Condition, Door Closed.
SOI 01.05 FV

SCHEMATIC DIAGRAMS

OVEN THERMAL
CUT- OUT 125°C
STOP SWITCH
OVEN THERMAL
CUT- OUT 125°C
STOP SWITCH
32/33
MAGNETRON
THERMAL
HIGH VOLTAGE
CUT- OUT 125°C
TRANSFORMER
MONITORED
MONITOR
SWITCH
LATCH SWITCH
* INDICATES COMPONENTS WITH
POTENTIAL ABOVE 250V
MAGNETRON
HIGH VOLTAGE
THERMAL
TRANSFORMER
CUT- OUT 125°C
MONITORED
MONITOR
LATCH SWITCH
SWITCH