Technical Equipment; Temperature Safety Device; Fan After-Running; Measure Against Wrong Electrical Connection - Electrolux COOKING Service Manual

Built-in appliances and floor-mounted stoves with avantgarde input electronics
Hide thumbs Also See for COOKING:
Table of Contents

Advertisement

5.

Technical equipment

5.1

Temperature safety device

With built-in appliances, there is a temperature fuse on the side of the air channel that switches off
the appliance in the event of overheating. The measured temperature value during a cutoff is 90°C.
Fig.: Built-in position - Temperature fuse
Notes:
-
-
5.2

Fan after-running

The cooling fan switches on automatically when putting the appliance into operation. First it is in
operation to keep cool the appliance surfaces. After the oven was switched off, the fan continues
running to cool the appliance and then switches off automatically at a centre of gravity temperature
of the muffle of approx. 120°C-130°C. The post-operative ventilation is controlled via the
electronics.
Note:
-
-
5.3

Measure against wrong electrical connection

Not provided.
DGS-TDS-N 05.09 A. B. © Electrolux
for wiring diagram see chapter 7
Deviations possible with floor-mounted stoves
for wiring diagram see chapter 7
Deviations possible with floor-mounted stoves
- 24 -
599 521 367
EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ovc 2000Ovc 1000Hoc 2000

Table of Contents