Step 2 Framing The Fireplace; Step 3 Installing The Vent System; Step 4 Securing The Fireplace; Step 5 The Gas Control Systems - Heat & Glo 6000PLUS Owner's Manual

Vented gas fireplace
Table of Contents

Advertisement

Step 2. Framing the Fireplace
Fireplace framing can be built before or after the fireplace is
set in place. Framing should be positioned to accommo-
date wall coverings and fireplace facing material. The dia-
gram below shows framing reference dimensions.
CAUTION: MEASURE FIREPLACE DIMENSIONS AND
VERIFY FRAMING METHODS AND WALL COVERING
DETAILS BEFORE FRAMING.
Framing should be constructed of 2 X 4 lumber or heavier.
WARNING:
To ensure proper clearances
the front framing header
must be installed on its
narrow edge and to the front
of the frame.
A. 42"
B. 38 1/2"
Figure 3.
Framing Dimensions
Step 3. Installing the Vent System
WARNING: REFER TO THE HRV200PLUS
!
INSTALLATION MANUAL FOR PROPER
VENTING CONFIGURATIONS FOR THE
6000PLUS GAS APPLIANCE.
C. 22"
Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05
Step 4. Positioning, Leveling, and
Securing the Fireplace
To properly position, level, and secure the fireplace:
• Place the fireplace into position (see Figure 4).
• Level the fireplace from side to side and from front to
back.
• Shim the fireplace with non-combustible material, such
as sheet metal, as necessary.
• Secure the fireplace to the framing by nailing or screwing.
WARNING:
To ensure proper clearances
the front framing header
must be installed on its
narrow edge and to the
front of the frame.
Figure 4. Proper Positioning, Leveling,
and Securing of a Fireplace
Step 5. The Gas Control System
WARNING: THIS UNIT IS NOT FOR USE WITH
!
SOLID FUEL.
The gas control system used with this model is the Intellifire.
Intellifire System
The Intellifire system includes a 3V control valve, electronic
module, and intermittent pilot.
WARNING: CONTINUOUS 110-120 VAC SER-
!
VICE MUST BE WIRED TO THE FIREPLACE
JUNCTION BOX.