Condenser Fan - GE ZIB240P Technical Service Manual

Bar refrigerator with icemaker
Table of Contents

Advertisement

Condenser Fan

Run diagnostic mode 12 to test the circuit
between the power supply board, compressor,
and the condenser fan. (
.)
Service Information
Voltage at L2 to N at the wiring junction box
should be 120 VAC. Condenser fan motor
resistance (black and gray wires) should be
approximately 135 Ω.
To remove the condenser fan motor:
The condenser fan motor can be removed from
the machine compartment without removing the
fan shroud.
1. Slide the fan blade off the motor shaft.
2. Remove the clips that hold the fan motor in
place (depress the tabs on each clip and lift
upward).
Holding Clips
3. Disconnect the fan motor at the wiring
junction box. Remove the condenser fan
motor.
See Diagnostics and
To remove the condenser fan motor and
shroud:
The condenser fan motor and shroud assembly
can be removed as one unit.
1. Remove the 3 Phillips-head screws that
hold the condenser fan motor and shroud
assembly in place.
Note: The 3 Phillips-head screws are located
on the base plate of the machine compartment.
The screws are mounted from underneath and
can only be accessed by tilting the refrigerator or
placing it on its side.
2. Disconnect the fan motor at the wiring
junction box.
3. Tilt the condenser fan motor and shroud
assembly under the compressor discharge
line and slide it out of the machine
compartment.