Outdoor fan motor
Outdoor coil
Outdoor fan
Outdoor air flow
Outdoor Sound pressure
Outdoor Sound power
Outdoor unit
Refrigerant type
R407c
Design pressure
Refrigerant piping
Additional refrigerant charge
over 5m
Expansion device (Capillary)
Operation temp
Ambient temp
Application area
Remarks:
1.Cooling capacities are based on indoor air temp. 27℃ DB, 19℃ WB and outdoor air temp. 35℃ DB,
and 24℃ WB. Heating capacities are based on indoor air temp. 20℃ DB, 15℃ WB and outdoor air
temp. 7℃ DB, and 6℃ WB.
2. Indoor Sound Pressure level is measured in free field (JIS 9612 std) at 1m distance.
Outdoor Sound Pressure level is measured in hemispherical field, at 4m distance from the unit.
these values are normally somewhat different as a result of ambient condition.
Model
Brand
Input
Capacitor
Speed
a.Number of rows
b.Tube pitch(a)xrow pitch(b)
c.Fin spacing
d.Fin type (code)
e.Tube outside dia.and type
f.Coil length x height x width
g.Number of circuits
Type and Diameter
(LPA) @cooling
(LWA) @cooling
Dimension(W*H*D)
Packing (W*H*D)
Net/Gross weight
Liquid side/ Gas side
Max. refrigerant pipe length
Max. difference in level
Main
Sub
W
uF
r/min
mm
mm
mm
mm
mm
m3/h
dB(A)
dB(A)
mm
mm
Kg
g
MPa
mm(inch)
m
m
g/m
mm
mm
m2
5
YDK53-6K
Welling
125
3.5
800
2
25.4x22
1.4
Hydrophilic aluminium
Ф9.53,innergroove tube
797X660X44
4
Propeller
2500
59
845X695X335
970X770X395
62/67
2000
2.8
Ф9.53/Ф16.0
20
10
65
Φ3.6*2.1*700
Φ3.6*2.1*600
17-30
—7-43
34~49